ANCOR SDN BHD
Tel: +6012-921 3877 ;
       +603-58797121
Fax:+6018-635 1593
Email: info@ancor.com.my ;
           ancor.my@gmail.com
D-2-4, Setia Walk,
Pusat Bandar Puchong,
47160 Puchong, Selangor
   Home      Omega Instruments      Rotameters
 
 
 
 

Rotameters

Measure the flowrate of liquids and gases, rotameters have a linear scale, a relatively long measurement range, and low pressure drop. They are simple to install and maintain.
 
 
 
 
FL-1,2,3,4,5,6,7,8GP
 
Multi-tube Rotameters/Gas Proportioning Rotameters
 
 
  • ±2%FS Accuracy
  • Back Pressure Compensated for Accurate Blending
  • Blend Up To Three Gases
  • Save on Cost of Custom Gas Mixtures
  • Vary Concentrations With Operating System
  • For Use With 150 mm Flow Tubes
 
FL2AA Series
 
Multiple Tube Rotameters
 
 
 
  • Interchangeable 150 mm Flow Tubes
  • Variety of Flow Configurations
  • ±2% FS Accuracy
  • Scales Designed to Minimize Parallax and Eye Fatigue
  • Aluminum or 316 SS End Fittings
 
FL-10 Series
 
Rotameter for Liquid Flow
 
 
 
  • Chemically Inert Wetted Components
  • Removable Protective Shield
  • Individually Leak Tested
 
 
FL-75
 
Low Cost Industrial Rotameters With Capacities: 0.5 to 200 GPM of Water
  •  Accuracy Scale: 127 mm (5"), Direct Reading on Tube
  • Metering Tubes: Acrylic
  • Floats: 316 SS
  • Float Stops: Polysulfone
  • Guide Rods: 316 SS
  • O-Rings: EPR End
  • Fittings: PVC
  • Direct Reading Scales
  • Shatter Resistant Construction
 
FL-86 Series
 
All Plastic Rotameters
 
 
 
  • Capacity: 0.5 to 100 GPM water (PTFE float)
  • Metering Tube Material: Polysulfone
  • Accuracy/Repeatability: ±6% FS/ ± 1%
  • Scale Length: 127 mm (5")
  • Float: PTFE
  • Fittings: PVDF
 
FL600
 
Stainless Steel Frame Flowmeters
 
 
  • Accuracy: ±3% of full scale
  • Repeatability: ±1%
  • Scale: 127 mm (5")
  • Wetted Parts: 316 stainless steel borosilicate glass, EPR O-Rings
  • Max. Temperature: 93°C (200°F)
  • Connections: FNPT
 
FL-800
 
Economical Purge Rotameters
 
 
  • Accuracy: ±4% full scale
  • Body and Tube: polycarbonate
  • Floats: black glass, carbide, or stainless steel
  • Temperature: 66°C (150°F) max @ 0 psig
  • Pressure: 100 psig max@
  • 21°C (70°F)
  • Fittings:Standard: Brass
     
 
FL900
 
Heavy Duty Flowmeters With Stainless Steel Enclosures
 
  • Heavy Duty 304 SS Case and Covers
  • 316 SS Rotatable Fittings Feature Dual Ports for Vertical or Horizontal Mounting
  • Unique Float Stop Design Allows Internals to Be Removed and Replaced Without Disturbing Tube or Shield
 
Fl-1200 Series
 
Economical Purge Rotameters
 
  • ±10% Full Scale Accuracy
  • ± 1/2% Full Scale Repeatability
  • Integral Needle Control Valve
  • Side Plate Construction
  • Direct Reading Air and Water Scales
  • 316 SS and Brass Construction Available
 
FL-1500A
 
High Accuracy Rotameters
 
 
  • ±2% Full Scale Accuracy
  • ±½% Full Scale Repeatability
  • Glass and Stainless Steel Construction for Broad Media Compatibility
  • Correlation Equations for Use with Many Fluids
  • Side Plate Construction
  • 250 mm (9.85") Scale
 
FL-1600A
 
Heavy Duty Industrial Rotameters

  • ±2% Full Scale Accuracy
  • ±1/2% Full Scale Repeatability
  • Dowel-Pin, Side Plate Construction
  • 10 to 100% of Flow Scale
  • Correlation Equations Permit Use with Any Fluid
  • Packing Glands for Industrial Installations
 
FL-2000
 
Acrylic Flowmeters
 
 
  • Easy-to-Read English or Metric Scales
  • Water Ranges from 4 CCM to 20 GPM, Air Ranges from 40 CCM to 4000 LPM
  • Threaded Brass Inserts for Quick Installation
  • Easy Disassembly and Assembly for Maintenance
 
FL-2500
 
Direct Read Acrylic Rotameter Kits
 
  • Fittings: 1/8 NPT female connections, built-in needle valves and seal plugs, brass or stainless (model dependent)
  • Easy-to-Read Dual English and Metric Scales
  • Interchangeable Scales for 6 Common Gases and Water
  • Meters are Offered With or Without Built-In Needle Valves
 
FL-3000SA Series
 
PTFE Rotameters with PTFE Valves
 
  • Max. Pressure: 100 psig
    Max. Temperature: 66°C (150°F)
    Connections: 1/8 FNPT
  • Excellent Chemical Compatibility for Use with Corrosive or Ultra-Pure Fluids
  • ±2% of Full Scale Accuracy
  • Shield Magnifies Scale for Accurate Readings
 
FL3200, FL3300, FL3400, FL3500 Series
 
65 AND 150 mm Rotameters
 
  • ±2% FS Accuracy
  • Non-Rotating Seal Spindle
  • Easy-to-Read Scale Design
  • Special Dimensions for Interchangeability
 
FL-3600 FL-3700 FL-3800 FL-3900
 
65 mm and 150 mm Rotameters
 
  • Scales: 65 or 150 mm arbitrary scale
  • Accuracy: ±2% full scale (±5% FS on FL3607/3707 and FL3845/3945 models)
    Repeatability: ±0.25% full scale
  • Connections: 1/8 FNPT, horizontal
  • Flow Tube: Borosilicate glass
 
FL4000 Series
 
OEM Style Acrylic Rotameters
 

  • Water Ranges: 125 psig @ 21°C (70°F); 54°C (130°F) at 0 psig
  • Air ranges: 100 psig @ 21°C (70°F); 38°C (100°F) @ 0 psi
  • Full Scale
  • Accuracy/Repeatability:
      FL4200: 6/2%
      FL4300 & FL4400:4/1%
      FL4500: 3-1/2%
      FL4600: 2-1/2%
 
FL-5000
 
Glass Tube Flowmeters
E-Z Tube Change With Magnifying Front Shield
 
  • Accuracy:
    65 mm (2.5"): scale ±5%
    150 mm (5.9"): scale ±3%
  • Back Plate: Aluminum
  • Standard Seals: 
  • Aluminum with Buna; stainless steel with FKM
  • Tube: Borosilicate glass
  • Pressure: 200 psi
  • Temperature: 93°C
 
FL7000 Series
 
OEM Style Acrylic Rotameters
 
 
  • 50 mm, 75 mm, 100 mm, 127 mm and 250 mm (1.97", 2.96", 5" and 9.85") Scale Lengths
  • Floats Are Rod-Guided in Most Models
  • Direct Reading Scales
 
FL-7100 Series
 
Direct Reading Analog Display Flowmeters
 
 
  • ±3% FS Accuracy
  • 120 mm (4.7") Scale Length
  • Dual Reading Scale
  • Stainless Steel and PVC Models
  • In-Line NPT Connections
  • All 316 Stainless Steel or PVC with Hastelloy Internals
 
FL30000
 
Economical Flowmeters For Measuring Water In a Closed Pipe System
  • Direct Reading Scales
  • Impact-Resistant Machined Acrylic Body
  • Easy-to-Read Scales
  • Wear- and Corrosion-Resistant 316SS Floats
  • 1 to 8" Pipe or Copper Tube Connection
 

 
FL45100
 
In-line Flowmeters With Half Union Adaptors
 
  • Accuracy: ±3%
  • Meter Body: Molded polysulfone
  • O-Ring Material: FKM
  • Float: 316 SS standard; Hastelloy¨ C optional
    Temperature Limit: 100°C (212°F) at 0 psi
  • Pressure Limit: 10 bar (150 psi) at 21°C (70°F)
 
FL-45200A
 
High-capacity In-line Flowmeters
 
  • Direct Reading Scales
  • One-Piece Molded Polysulfone
  • Floats Available in 316SS or TFE
  • 316SS Float Guide Reduces Float Oscillation
  • Low Pressure Drop
 
FL46300
 
In-line Flow meters
 
 
  • Accuracy: ±5%
  • Meter Body: Acrylic
  • O-Ring Material: FKM
  • Float: 316 SS (PVC for FL46302)
  • Temperature Limit: 65°C (150°F) at 0 psig
  • Pressure Limit: 150 psig at 21°C (70°F)
  • Pressure Drop: 2 psi max
 
 
FL50000A
 
Panel Mount Flowmeters
 
 
  • Temperature Limits: 48°C (120°F) at 0 psi (3/4 and 1 MNPT units) 93°C (200°F) at 0 psi (1/4, 1/2 and 3/8 MNPT units)
  • Pressure Limits: 120 psi at 21°C (70°F) (3/4 and 1 MNPT units) 250 psig at 21°C (70°F) (1/4, 1/2 and 3/8 MNPT units)
  • Pressure Drop: 2 psi max
  • Adaptor: 1/4" and 1" are PVC, all others are glass-filled polypropylene
 
FLD Series
 
Direct Read Rotameters
 
 
  • Direct Read Rotameters for Air, Water, N2, H2, CO2, Ar, He, and O2
  • Maximum Operating Pressure: 200 psig/13.8 bars
  • Connections: 1/8 NPT female inlet and outlet connections
  • Maximum Operating Pressure: 200 psig/13.8 bars
    Maximum Operating Temperature: 121°C
 
FLD100 Series
 
Stainless Steel Frame Industrial Flowmeters
 
  • Heavy Duty Stainless Steel
  • Thick Polycarbonate Safety Shields
  • Fluted or Plain Tapered Tubes
  • Direct Reading Metric and English System Scales
  • Unique Design Facilitates Ease of Maintenance Cleaning Processes
 
FLD1000 and FLD2000 Series
 
Direct Read In-Line and Panel Rotameters
  •  Rigid, Compact Construction
  • Dual, Rotatable, Direct Reading Scales for Air and Water
  • Graduations Reflect Both Metric and English Systems
  • Vertical In-line or Panel Mount
 
 
FLSW3400 and FLSW3500 Series
 
Rotameter with Alarm
 
  • Accuracy: ±2% of full scale
    Repeatability: 0.5% of full scale
    Ambient Temperature: 0 to 70°C (32 to 158°F)
    Maximum Pressure: 200 psig
    Connections: 1/8" FNPT
  • HIGH or LOW Alarms
  • Compact Design
  • Liquid or Gas Applications
 
FLT Series
 
ACCESSORY FLOWTUBES For Use with FL-3000 Series Rotameters, Multitube Assemblies and Gas Proportioners
 
  • Multitube Assemblies
  • Gas Proportioners
 
 
 
 
 
 
Ancor Sdn Bhd
D-2-4, Setiawalk, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: +6012-921 3877; +6018-623 5135,
Fax: 6018-635 1593  
Email: info@ancor.com.my ; ancor.my@gmail.com