Aalborg- Model V brass or stainless steel medium range
model V brass or stainless steel medium range
model V brass or stainless steel single flow tube rotameter for medium flow rate measurement
Design Features
rigid compact construction
dual rotatable direct reading scales for air and water
graduations reflect both metric and English systems
vertical in-line or panel mount versions available
flow ranges from 4 to 20 LPM water and 140 to 900 SLPM air
model V brass or stainless steel medium range
Incorporating
traditional rotameter precision glass technology, these rugged brass and
stainless steel flow meters offer accurate and economical solutions to
medium flow range measurements. V meters are designed with unique
rotatable scales of dual air-water direct reading graduations showing
SCFM and SLPM (air), as well as GPM and LPM (water) markings.
SPECIFICATIONS
SCALES rotatable direct reading air (SCFM-SLPM) and water (GPM-LPM)
STANDARD ACCURACY ±5% FS
MAXIMUM OPERATING PRESSURE 150 psig at 200°F (10.3 bars at 93°C)
MAXIMUM OPERATING TEMPERATURE 250°F (121°C)
MATERIALS OF CONSTRUCTION
FLOW TUBES heavy walled precision formed borosilicate glass