Gas Management Accessories
Gas Safety Cabinets
GC Series
Gas Safety Cabinets
- Door and window latch and close automatically
- 1/4" wire reinforced safety glass
- All welded construction 11 Gauge steel
- Louvers at bottom of door
- Flush mounted stainless steel paddle latch
- Adjustable brackets for precise pigtail alignment
- Exhaust vent located on top of cabinet is 6" diameter x 3" high
- Removable white back panels mount to inside rear cabinet
- Cylinder brackets accommodate 7" to 9" diameter cylinders
- 165?F sprinkler head on top of cabinet with bees wax coating
- Epoxy painted exterior texture with smooth interior finish
|
Regulator Brackets
Wall Mount and Brackets
Use with Header Manifolds.
|
Pigtails
Pigtails
Suitable for cylinder & terminal connector, coil tubing & pigtail design.
Features
-
Designed for use between cylinder and piping system
- Maximum Pressure: GFPT and GFPS Series, 3000 psi; GRPS Series, 4500 psi
- Temperature Range: GFPS and GRPS Series, -325?F to 850?F (-200?C to 454?C); GFPT, -65?F to 450?F (-53?C to 230?C)
- Oxygen Service: Meets CGA G4.1 Specifications for cleanliness
|
Gas Pressure Alarms & Header Bars
Alarms
- Connect to a Pressure Switch or Contact Gauge
- LED display 1, 2 and 4 gases
- Audible alarm
- Visual alarm
- Mute button
- Connection cord for alarm
- Voltage: 110VAC or 220VAC (optional)
|
Header Bars
- Modular design for easy installation on future expansion
- Outlet connections are available in both Genlok tube fitting and FSR fittings
- Maximum inlet pressure of 3000 psi
- 100% tested to ensure there are no leaks
|
Pressure Gauges
GA20SL/GRA20SL/GE20SL/GRE20SL Series
Electronic Contact Gauges
- Switch opens on decreasing pressure
- Adjustable betweem 5 and 80% of the scale range
- Maximum power: 10 Watts DC, 12 VA AV
- Maximum switch voltage: 28V AC/DC
- Wetted area and casing: 316L
- Temperature: -40° F~158° F
- Connection: 1/4" NPt
- Accuracy: 3-2-3 (2%)
- Potential-free relay
|
GU20SL Series
Ultra High Purity Gauges
- This 2" pressure gauge is ideal for semiconductor processing
- High
purity gas delivery
- Purge panel system
- High purity liquid delivery
applications.
|
G20P/G20PV/GR20/GR20SL/GR20SLV Series
High Purity Gauges
- Designed for use with regulator
- Easy control of outlet flow
|
Purge Tools & Fittings
SL-P101
Purge Tools
- Straight purge connection
- For connection to regulator high pressure inlet
- For regulators and down stream devices
- Purge gases delivered from regulators downstream
- Suitable for circular purging
|
SL-P102
Purge Tools
- "T"-design purge connection
- For connection between regulator and cylinder
- Purge of whole gas system
- Purge gases delivered from regulator downstream
- Suitable for circular purging
|
SL-P103
Purge Tools
- Cross design purge connection
- For connection between regulator and cylinder
- Purge of whole gas system, diapharam valve controls purging for cylinder valve
- Purge gases relieved from purged port or regulator downstream
|
Vacuum Generators
- 316L Stainless Steel construction
- Cleaned, welded assembled, tested and packaged in Class 10 clean room
- Internal surface finish 0.4 um?
- 660 mmHg (100 Torr) vacuum generated with a minimum source nitrogen pressure of 75 psig
- Helium leak tested
- Used in gas delivery systems to assist in purging piping systems
|
Tube Fittings
- GENTEC Tube Fittings consist of 4 main compartments: front ferrule, back
ferrule, nut and body.
- With superior mechanical designs, these fittings
provide excellent sealing and tube-gripping actions that result in
leak-tight tube connections and torque free assembly.
- Only 1-1/4 turn
{3/4 turn for tubing less than 3/16" (4mm)} is needed for installation
to guarantee consistent drive of the seal against high pressure and high
vacuum conditions.
|
|
Gas Cylinder Connections
Cylinder Connections
- Nuts and nipples are designed for regulator inlet connections.
|
Flashback Arrestors
- Model Number: GRE20-3000
- Monitor gas pressure
- Provides signal for alarm system
- Range: 0-3000 psig
- Alarm pressure preset: 0-3000 psig
- Connection: 1/4” NPT
- Rear entry
- Avaliable to SL250 changeover system
|
Filters
Inline Filter
- Stainless steel 316 material for body and filter element
- Sintered filter element provides fine filtration
- Maximum working pressure:
- F2&F4: 3000 psig (200 bar)
- F6&F8: 2500 psig (172 bar)
- Working temperature: -18F - 900F (-28C - 482C)
- Maximum differential pressure: 1000 psig
- End connections include: GENLOK® tube fittings, NPT fittings, BSP/ISO tapered, FSR face seal fittings
- 100% tested to ensure optimal performance
T-Type
• Easily removable filter element for cleaning or replacement without removing filter from the system
• Stainless steel 316 material for body and filter element
• Sintered filter element provides fine filtration
• Maximum working pressure: 6000 psig (400 bar)
• Working temperature: -18F - 900F (-28C - 482C)
• Maximum differential pressure: 1000 psig
• End connections include: GENLOK® tube fittings, NPT fittings, BSP/ISO tapered, FSR face seal fittings
• 100% tested to ensure optimal performance
|
|
|
|
|
|
Ancor Sdn Bhd
D-2-4, Setiawalk, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: +6012-921 3877 , 03-58797121
Email: info@ancor.com.my ; ancor.my@gmail.com
|
|
|
|
|