Percent Oxygen Analyzers

 
 
 
 
 
Model 210BR
 
Hazardous area permanent mount
percent oxygen analyzer
 
  • Percent oxygen - 0.00% to 25.0%
  • H2S resistant sensor - up to 10ppm H2S resistant standard, 500ppm H2S resistant optional
  • Hazardous area - CSA approved Class 1 Division 1 Group BCD
 
 
 
 
Watchdog
 
Low cost Division 2 area permanent
mount trace oxygen analyzer
 
  • Trace oxygen - 0.00ppm to 25.0%
  • Ultra-fast come-down H2S resistant sensor - up to 10ppm H2S resistant standard, 500ppm H2S resistant optional
  • Designed to meet Class 1 Division 2 hazardous area requirements
  • Patented cell block minimizes sample volume, fittings and eliminates tubing.
 
 
 
 
 
Model 201RS
 
General purpose permanent mount
percent oxygen analyzer
 
  • Percent oxygen - 0.00% to 25.0%
  • Optional ranges 0-1000ppm, 0-50%, 0-100%
  • Optional sensors for inert gas or High level CO2-containing gases
  • Positive pressure sample
 
 
Model 201RSP
 
General purpose permanent mount
percent oxygen analyzer. 
 
  • Percent oxygen - 0.00% to 25.0%
  • Optional ranges 0-1000ppm, 0-50%, 0-100%
  • Optional sensors for inert gas or High level CO2-containing gases
  • Ambient pressure sample
  • Built-in pump
 
 
Model 70
 
General purpose percent
oxygen probe
 
  • Percent oxygen in non-flammable background gas, 0.00-25.0%
  • Optional ranges 0-50%, 0-95%
  • Long life (10 year) ultra-stable zirconium oxide sensor
  • Insensitive to barometric pressure or temperature changes
 
 
Model 111
 
Percentage oxygen measurement
in non-flammable gases
 
  • Percent oxygen in non-flammable samples
  • General purpose portable analyzer
  • Extremely stable, long-life sensor
  • Virtually unaffected by temperature changes
  • Virtually unaffected by barometric pressure changes
  • Virtually unaffected by humidity changes
  • Virtually unaffected by flow rate changes
 
 
 
 
Model 111P
 
Percentage oxygen measurement in
non-flammable gases
 
  • Single measurement range; four datalog ranges selectable.
  • High resolution 3 ½ digit LCD
  • RFI protected
  • Data logger
  • USB virtual comport communication for advanced features
  • Power requirements: 115/230VAC to 12VDC battery charger
 
 
Model 111B
 
Percentage oxygen measurement in
non-flammable gases
 
  • Low minimum detection limit 0.01% oxygen (25% version)
  • Excellent repeatability and stability
  • Extended operating temperature range to 130°F
  • Fast upscale/downscale response times
  • Long life sensor, 10 year life expectancy
  • Unaffected by changes in flow rate from 0.1 to 2.0 SCFH
  • Compact portable
 
 
 
 
 
 
 
 