GPR-1200 & GPR-3500
Fast Responding Oxygen Analyzers
- Measurement ranges from 0-10 ppm up to 0-100% O2
- Accuracy of better than 2% of range
- 24-32 months sensor life span (in normal use)
- Up to 30 days battery life
- Internal pump option
- 0-1V output
- XLT sensor options for CO2 backgrounds
- Rugged industrial enclosures
|
GPR-1000, GPR-1100,
GPR-2000 & GPR-3500
Portable Oxygen Analyzers from
0.1 ppm up to 100% oxygen
- Rugged- made to last in field operation
- Easy to use
- Up to 30 days battery life (40 hours with pump)
- Measurement ranges from 0-10 ppm up to 0-100% O2
- 24 to 32 months sensor life span (in normal use)
- Lightweight – 2.5Kgs
- Internal pump option
- 0-1V output
- XLT sensor options for CO2 backgrounds
|
GPR-1600, GPR-2600, GPR-3100
Industrial Gas Oxygen Analyzers
- Easy to use HMI
- High accuracy ( ±0.02 ppm in lowest range)
- Four measurement ranges with manual or auto-ranging
- 24 month sensor life with normal usage
- Sample in CO2 backgrounds with XLT sensor
- Bench, rack or wall mounting options
- Two Alarms
- Integrated bypass valve (for GPR-1600)
- Easy access and sensor replacement
- Easy to use HMI
|
AII-3000 Series, Palm O2
Nitrox Analysers for Diving
- 0-100% O2 measurement range
- Long sensor life up to 60 months (AII-3000)
- Battery life up to 13,000 hours of continuous use (Palm O2)
- Integrated or remote sensors
- Fast response time of T90 in <10 seconds
|
GPR-1900/MS & GPR-2900
Oxygen Analyzer with Remote Sensor
- Measurement ranges from 0-1ppm up to 0-100% O2
- Barometric pressure and temperature compensation
- Accuracy of better than 2% of range
- Two user configurable alarms
- Range ID output
- 12-28 V DC or mains powered options
- XLT sensor options for CO2 backgrounds
|
PI2-UHP 50/100 and
PI2-MS 500/1000
Oxygen Analyzers for Ultra-High Purity Gases
- Measuring trace O2 in ultra-pure Ar, H2, He and N2
- LDL to less than 100 ppt
- Low cost of ownership
- User friendly and easy to operate and maintain
- Fast recovery from process upsets
- Integrated bypass sample system as standard
- Optional auto calibration system with true zero feature via O2 scrubber
|
GPR-1500 GB & GPR-2500 GB
Oxygen Monitor for Glove Boxes and Confined Spaces
- Measurement ranges from 0-10ppm up to 0-25% O2
- Accuracy of better than 2% of range
- 24 months sensor life span (in normal use)
- 4-20 mA output
- 18-24V loop powered
- XLT sensor options for CO2 backgrounds
|
GPR-35, GPR-2500 SN (ATEX), GPR-2800 IS
Room Oxygen Deficiency Monitors with Alarm
- Low maintenance with typically 32 months oxygen sensor life
- Audible and visual oxygen deficiency alarm available
- Up to four measurement ranges
- Accuracy of <2% of span
- Mains power with battery back-up (GPR-35)
- Remote oxygen sensor & pump options (GPR-35)
- Analog output for connection to DCS
- 12-28 V DC operation (GPR-2500 versions)
|
GPR-1500 Series
Trace Oxygen Analyzer for Wall Installations
- Multiple user-configurable oxygen measurement ranges available
- General purpose or intrinsically safe (ATEX) models
- Fast recovery from exposure to air
- Can measure in pure CO2 with XLT sensor
- Two alarms with GPR-1500 A analyzer model
|
|
GPR-2500 Series
Wall Mounted Percent Oxygen Analyzer
- Advanced galvanic electrochemical sensors
- Measuring oxygen in ranges: 0-1% up to 0-100% (model dependant)
- Accuracy of better than 2% of selected range
- Auto-ranging or fixed range (user selectable)
- Long lifespan of the GPR sensor of 32 months and more
- Simple to use HMI
|
|