ANCOR SDN BHD
Tel: +6012-921 3877 ;
       +603-58797121
Email: info@ancor.com.my ;
           ancor.my@gmail.com
D-2-4, Setia Walk,
Pusat Bandar Puchong,
47160 Puchong, Selangor
   Home      Aalborg- Model L PTFE-PFA flow meters
         
 
 
 
 
 
 
 
 

model L PTFE-PFA flow meters

 
model L rugged PTFE-PFA flow meters offer solutions to low to medium flow range measurements
 
 

Design Features
 
  • chemically inert components constructed from PFA PTFE and PCTE
  • structurally rigid frame
  • overlapping flow ranges are available for water from 5 mLPM (0.00132 GPM) to 45 LPM (12 GPM).
  • individually leak tested
Incorporating the principles of traditional rotameter flow technology, these rugged PTFE-PFA flow meters offer solutions to low to medium flow range measurements of highly corrosive or ultra-pure liquids. Model L Meters are constructed of inert materials such as PFA, PTFE and PCTFE. The design represents a unique combination of a rugged mechanically rigid frame and the chemically inert wetted parts.

Flow meters are also resistant to external, ambient corrosives. For the protection of personnel each flow meter is supplied with a safety shield.

Flow meters are supplied with or without built-in needle valves and they are panel mountable, by means of panel nuts.

 
 
 
 
 
 
 
 
 

PRINCIPLES OF OPERATION
 

A cylindrical float freely moving inside a tapered flow tube comprises the flow measurement element of PTFE - PFA flow meters. The translucent PFA flow tube is installed vertically in-line in the liquid stream.

As flow takes place the float is propelled up inside the flow tube. The area between the float and the inside diameter of the flow tube gradually increases with increasing flow and correspondingly the pressure lifting the float decreases until the weight of the float and its buoyant force come to equilibrium.

At equilibrium the top of the float is lined up with a scale graduation on the flow
tube denoting a discrete rate of flow.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SPECIFICATIONS

 

SCALES 0 to 10 markings

STANDARD ACCURACY ±5% FS
MAXIMUM OPERATING PRESSURE 100 psig (6.7 bars)
MAXIMUM OPERATING TEMPERATURE 250°F (121°C)

LEAK INTEGRITY individually leak tested and certified to a rating of 1 x 10-7 sccs of helium

 
 
MATERIALS OF CONSTRUCTION

 

FLOW TUBES PTFE, PFA

FLOATS PTFE
FRONT SHIELD polycarbonate
HOUSING PTFE
CONNECTIONS 1/4 inch FNPT to 3/4 inch FNPT based on model selected
 
 
 
 
 
 
 
 
 
 
 
 
 

Ancor Sdn Bhd
D-2-4, Setiawalk, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: +6012-921 3877 , 03-58797121