Oxygen Analyzers

 
 

Trace Oxygen Analyzers

Model 2010BR
 
Hazardous area permanent mount trace oxygen analyzer
 
 
    • Display reads oxygen from 0.05ppm up to 25.0% with no range changes
    • Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution
    • Field selectable analog output - 1-5V or 4-20mA, isolated.
     
     
     
     
     
    Model 1000RS
     
    Hazardous area portable trace oxygen analyzer
     
     
     
    • Trace oxygen measurement from 0.05ppm to 25.0%
    • Rugged, small, portable unit
    • Simple operation
    • Complete flow control and indication provided
    • Single quick-disconnect sample connection
    • Patented cell block provides purge capability
     
     
    Model 2001RS
     
    General purpose permanent mount trace oxygen analyzer 
     
     
    • Display reads oxygen from 0.05ppm up to 25.0% with no range changes
    • Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution
    • Analog output 4-20mA, isolated.
     
     
     
    Model 2001RSP
     
    General purpose permanent mount trace oxygen analyzer. Atmospheric pressure sample source
     
    • Display reads oxygen from 0.05ppm up to 25.0% with no range changes
    • Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution
    • Analog output 4-20mA, isolated.
     
     
     
    Model 2001RSM
     
    Multichannel general purpose permanent mount trace oxygen analyzer
     
     
     
    • Display reads oxygen from 0.05ppm up to 25.0% with no range changes
    • Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution
    • Analog output 4-20mA, isolated.
     
     
     
    Model 2001RSPM
     
    Multichannel general purpose permanent mount trace oxygen analyzer for atmospheric pressure samples
     
    • Display reads oxygen from 0.05ppm up to 25.0% with no range changes
    • Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution
    • Analog output 4-20mA, isolated.
     
     
    Model 2001LC
     
    General purpose rack mount trace oxygen analyzer
     
     
     
    • Display reads oxygen from 0.05ppm up to 25.0% with no range changes
    • Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution
    • Analog output 4-20mA, isolated.
     
     
    Watchdog
     
    Low cost Division 2 area permanent mount trace oxygen analyzer
     
     
     
    • Display reads oxygen from 0.05ppm up to 25.0% with no range changes
    • Analog output can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution
    • Field selectable analog output - 1-5V or 4-20mA, isolated.
     
     
     
     
     

    Percent Oxygen Analyzers

     
     
     
    Model 210BR
     
    Hazardous area permanent mount percent oxygen analyzer
     
    • Percent oxygen - 0.00% to 25.0%
    • H2S resistant sensor - up to 10ppm H2S resistant standard, 500ppm H2S resistant optional
    • Hazardous area - CSA approved Class 1 Division 1 Group BCD
    • Patented cell block minimizes sample volume, fittings and eliminates tubing.
     
     
     
     
     
    Model 201RS
     
    General purpose permanent mount percent oxygen analyzer
     
    • Percent oxygen - 0.00% to 25.0%
    • Optional ranges 0-1000ppm, 0-50%, 0-100%
    • Optional sensors for inert gas or High level CO2-containing gases
    • Positive pressure sample
    • Patented cell block minimizes sample volume, fittings & tubing.
     
     
     
    Model 201RSP
     
    General purpose permanent mount percent oxygen analyzer. Atmospheric pressure sample source
    • Percent oxygen - 0.00% to 25.0%
    • Optional ranges 0-1000ppm, 0-50%, 0-100%
    • Optional sensors for inert gas or High level CO2-containing gases
    • Ambient pressure sample
    • Built-in pump
     
     
     
     
     
    Model 201RSM
     
    Multichannel general purpose permanent mount percent oxygen analyzer
     
    • Percent oxygen - 0.00% to 25.0%
    • Optional ranges 0-1000ppm, 0-50%, 0-100%
    • Optional sensors for inert gas or High level CO2-containing gases
    • Positive pressure sample
    • Up to 5 sequenced sample inputs
     
     
     
     
    Model 201RSPM
     
    Multichannel general purpose permanent mount percent oxygen analyzer for atmospheric pressure samples
    • Percent oxygen - 0.00% to 25.0%
    • Optional ranges 0-1000ppm, 0-50%, 0-100%
    • Optional sensors for inert gas or High level CO2-containing gases
    • Ambient pressure sample
    • Up to 5 sequenced sample inputs
    • Built-in pump
     
     
     
     
     

    Model 201LC
     
    General purpose rack mount percent oxygen analyzer
     
     
    • Percent oxygen – 0.00% to 25.0%
    • Positive pressure sample
    • Patented cell block minimizes sample volume, fittings and tubing.
    • Compact size – easy installation
    • DC power 10-28VDC
    • Low power
    • Precision state-of-the-art electronics
     
     
     
     
    Model 70
     
    General purpose percent oxygen probe
     
     
     
    • Percent oxygen in non-flammable background gas, 0.00-25.0%
    • Optional ranges 0-50%, 0-95%
    • Long life (10 year) ultra-stable zirconium oxide sensor
    • Insensitive to barometric pressure or temperature changes
    • Fully Programmable
     
     
     
     
    Watchdog
     
    Low cost Division 2 area permanent mount trace oxygen analyzer
     
     
    • Trace oxygen - 0.00ppm to 25.0%
    • Ultra-fast come-down H2S resistant sensor - up to 10ppm H2S resistant standard, 500ppm H2S resistant optional
    • Designed to meet Class 1 Division 2 hazardous area requirements
    • Patented cell block minimizes sample volume, fittings and eliminates tubing.
     
     
     
     
    Model 111
     
    Portable Ultra-stable Percent oxygen analyzer
     
     
    • Percent oxygen in non-flammable background gas
    • 0-25% standard range
    • Optional ranges 0-50% or 0-95%
    • Long life (10 year) ultra-stable zirconium oxide sensor
    • Insensitive to barometric pressure or temperature changes
     
     
     
     
     
    Model 111P
     
    Portable Ultra-stable Percent oxygen analyzer for ambient pressure samples
    • Percent oxygen in non-flammable background gas
    • 0-25% standard range
    • 0-50% or 0-95% options
    • Long life (10 year) ultra-stable zirconium oxide sensor
    • Insensitive to barometric pressure or temperature changes
    • Battery powered
     
     
     

    Model 111B
     
    Portable Ultra-stable Percent oxygen analyzer for aerospace
     
    • Percent oxygen in non-flammable background gas
    • 0-25% standard range
    • 0-50% or 0-95% options
    • Long life (10 year) ultra-stable zirconium oxide sensor
    • Insensitive to barometric pressure or temperature changes
    • Battery powered
     
     
     
     
    Model 65
     
    Ultra-stable Percent oxygen probe
     
     
    • Percent oxygen probe
    • Long life ultra-stable zirconium oxide sensor
    • 0-25% standard range
    • 0-50% or 0-95% options
    • Insensitive to barometric pressure or temperature changes
    • Standard voltage output 0-2.5V
     
     
     
    More
     

    Model 60
    Low cost Percent oxygen probe
    • Percent oxygen probe
    • Ultra-low cost
    • 0-25% standard range
    • Optional ranges available
    • Standard voltage output 0-2.5VDC
    • DC power 7-24V
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     