Model 2010BR
Since 2004 the Model 2010BR has been the unquestioned
market leader, the industry-standard hazardous area trace oxygen
analyzer. Over the years it has been continuously refined to the point
that it now provides every feature you can possibly need – and many that
you may not have thought of - in a compact, easily installed low-cost
package. Many thousands of these analyzers are operating to
specification in the harshest environments all over the country.
Trace oxygen analyzers are essentially leak
detectors. AMI’s patented cell block allows the analyzer to be built
with almost no possibility of internal leaking, with minimal volume and
with front- panel sensor access. All sample handling components – the
flow meter, needle valve and a four-way sample/span/off selection valve –
are integrated into a solid metal block. Connections between them are
drilled passages. The result is a highly reliable sample system with all
necessary components provided, and a very fast “come-down” time – when a
sensor is replaced, or calibrated on air with a 1 minute exposure (at
70°F), it takes about 15 minutes for it to come down to below 10ppm.
Competitive analyzers typically take hours.
The AMI oxygen sensor is inherently faster than
competitive sensors due to its metallic body and large active electrode
area. The standard T2 sensor is also naturally resistive to hydrogen
sulfide up to 10ppm H2S over its warrantied life, while the T4 is
capable of resisting up to 500ppm H2S, with no scrubber material
required, and hence no maintenance or leakage issues.
The sensor is immediately accessible on the front
panel of the analyzer, and can be replaced in seconds. It is not
necessary to expose the sensor to air unshorted while installing it as
is the case with most analyzers (which significantly increases their
come-down time). As a result, although a span gas port is provided, it
is practical to accurately calibrate this analyzer on air in less than a
minute.
For low temperature operation an integral
(approved) explosion-proof heater can be supplied. This unit directly
heats the cell block and thus is extremely efficient, allowing operation
off a solar panel system down to -20F. It does not require additional
enclosures or wiring. For extreme environments down to -40F, an outer
insulated enclosure can be supplied, but no additional power is
required.
The analyzer is approved by CSA for operation in a
Class 1 Division 1 Group BCD hazardous area with a flammable gas as the
sample. No additional safety barriers are needed. The analyzer
can be calibrated and sensor replaced without declassifying the
area because the analytical electronics are intrinsically safe,
protected by internal safety barriers.
The electronic and software package is exceptionally
complete, and all features are provided as standard with no
additional cost (except for the heater). Even with the heater
it is capable of operating off a battery and solar panel, and it
logs power brown outs and failures should they occur. It also logs the
ambient and the sensor temperatures so can be used to alarm on the
failure of a catalytic heater if one is used in a remote location. It
tracks the life of the sensor, indicates the remaining life, logs the
calibration history and logs the oxygen readings over its operational
(output) range, and also tracks excursions of up to ten times that
range.
OVERVIEW
- Display reads oxygen from 0.05ppm up to 25.0% with no range changes
- Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution
- Field selectable analog output - 1-5V or 4-20mA, isolated.
- CSA approved to meet Class 1 Div. 1 Group BCD with a flammable sample
- Complete sample system built in to AMI’s patented cell block.
- Very rapid response time from air to low ppm levels.
- Easily replaceable sensor, no tools required.
- T-2 sensor resistant to 10ppm H2S standard. Optional T-4 resistant up to 500ppm H2S.
- Simple, versatile installation.
- Operates either off 117VAC or 12–24VDC with very low power consumption
- Available integral explosion-proof heater for cold environments
- Analog output can be easily calibrated to a SCADA system or flow computer.
- 2 independent, fully adjustable alarm settings with relaycontacts.
- Complete
alarm logic programming: latching or non-latching, open or close on
alarm, high alarm or low alarm, alarm-on delays and alarm hold-off.
Integral data logger: Logs data for 15 days @ 1min intervals and 30 days
@ 2min. intervals, etc.
- USB connectivity to a PC: Allows complete access to the internal functions and settings.
- ModBus: Industry standard protocol over RS485.
- Oxygen Sensor life indication.
- 10 user selectable output ranges
- 3 ½ digit LCD
- 2 fully adjustable oxygen concentration alarms
- Alarm delays
- Alarm hold off/Bypass
- RFI protected
- 1-5VDC or 4-20mA. isolated analog output signals
- USB virtual comport and Modbus Bidirectional RS485
- communication for advanced features.
- Datalog – 15 days oxygen reading recording at 1 minute per sample
- Calibration history – stores the last five calibrations with
- time, date, span factor and calibration gas.
- Brown-out history – stores the last five brown-outs and recoveries.
- Power up history – stores the last ten times the unit was
- powered up.
- Advanced analog output calibration.
- Power requirements: Choice of 12–24VDC or 115VAC power
- Low minimum detection limit 0.05ppm
- Excellent repeatability
- Extended operating temperature range
- Fast upscale/downscale response times
- Patented
Cellblock Technology: Allows for all components such as flow control
valve, flow meter, 3-way calibration valve, and compression fittings to
be an integral part of the cellblock, eliminating long lengths of tubing
and fittings.
- o Other benefits of this design include
compact size, faster response times and front panel sensor access
without the need for tools.
- Area Classification:
Approved by CSA International to UL and CSA standards as meeting
requirements for Class 1, Div. 1, Groups B,C,D with a flammable gas
sample
- Unaffected by changes in flow rate from 0.1 to 2.0 SCFH
- Wall mount or 2.0” pipe
- Compact size
- 2 year warranty for analyzer, parts and labor
- 6 month sensor warranty, life expectancy 1-2 years
- Requires AMI User Interface software