SL250 Series

The SL250 Series switchover system is designed with Gentec’s R21SL Series pressure reducing regulators to provide an uninterrupted supply of gas from two high pressure banks. The system will automatically switch from the primary bank to the reserve bank without flow interruptions. An optional audible and visual remote alarm is available to power the indicator lights for the system.

 
 
 
 
 
 
 
 

EX:  SL250

100

D

2L

2R

C350

S

1

SERIES

LAYOUT

MAX. OUTLET 
PRESSURE
OUTLET 
CONNECTION

LEFT STATIONS

RIGHT STATIONS

INLET 
CONNECTIONS

PIGTAIL

OPTIONS

SL250

A: 12” standard

50 psig

D: Diaphragm Valve

1 1

C320: CGA320

S: 316L

1: Alarm

 

 

100 psig

No Options: Blank

2 2

C350: CGA350

T: Teflon

3: Flashback arrestors

   

150 psig

Leave blank for no options

3 3

C540: CGA540

 

4: Filter

        4 4

C580: CGA580

 

No options: Blank

        5 5

C590: CGA590

 

Can choose multiple options

       

Blank for box only

Blank for box only

For other connections, please contact Gentec.

 

 

 
 
 
 
 
 
 
 
 
 
 

Semi-Automatic Switchover Manifolds

210/220 Series

GENTEC® 210 / B220 series semi-automatic system is designed for a continuous supply of high purity gases. It consists of a primary bank and a reserve bank of cylinders. Because of the differential pressure between the primary and reserve banks, the changeover takes place automatically when the primary bank is depleted to provide a continuous supply of gas from the reserve bank. However, in order to activate the next switchover, the regulators on both banks need to be readjusted upon changing the cylinders using the arrow indicator. Stable pressure output is provided by the second pressure regulator on the main line.

 
 
 
 

X:  SL210

A

150

D

 

 

C580

S

1

SERIES  

LAYOUT 

MAX. OUTLET
PRESSURE
OUTLET
CONNECTION

LEFT STATIONS 

RIGHT STATIONS
 INLET 
CONNECTIONS

PIGTAIL

OPTIONS

SL210 

A: 12” standard

(Header only)

50 psig

D: Diaphragm Valve 1/4" NPT(F)

1 1

C320: CGA320

S: 316L

1: Alarm

SL220

 

100 psig

Leave blank for no valve

2 2

C350: CGA350

T: Teflon

2: Flashback arrestors

B210

 

150 psig (for SL210 only)

 

3 3

C540: CGA540

 

3: Filter

B220

 

 

  4 4

C580: CGA580

 

R: Relief valve

        5 5

C590: CGA590

 

Leave blank for no options

       

 

 

C660: CGA660

 

Can choose multiple options

 

         

Other connections are available

   
           

No Pigtail

00: 1/4" NPT(M)

   
 
 
 
 
 
 
 
 
 
 
 

Semi-Automatic Switchover Manifold

P2400 Series

GENTEC® P2400 Series Speciality Gas Control Panel is a dual bank semi-automatic changeover system, providing a continuous supply without interrupting the system during cylinders(s) replacement. P2400 Series is designed with dual pressure reduction to provide study outlet pressure and is applicable for purity gas usage in research laboratories, clean rooms and gas analyzing.

 
 
 
 
 
 
 
 
EX: P2400 S P D H K  
Series         Gauge Optional
P2400: S: Stainless steel P: PU D: 3000 psig L: 25 psig K: psig/ kPa C: Contact Gauge
        K: 50 psig P: psig / bar  
        I: 100 psig    
        H: 150 psig    
 
 
 
 
 
 
 
 
 
 
 

Semi-Automatic Switchover Manifold

PD3400 Series

GENTEC® PD3400 Series Specialty Gas Control Panel is a Semi-Automatic Changeover System which provides for continuous gas supply without interrupting the system during cylinder changeout. When the primary bank is nearly depleted, a changeover will occur. The reserve bank will then begin to supply gas to the alternate cylinder. The inlet valve on each bank provides the user additional safety while replacing the cylinder(s) on the empty bank before the next changeover occurs. The HP vent valves may be used to purge the lines of any residual contamination. The line regulator executes a second stage pressure reduction, providing a consistent outlet pressure and flow. Available in both Brass and Stainless Steel.

 
 
 
EX: PD34 1 6 S K D H K  
Series

Diaphragm Valve

Configuration

Inlet Connection Body Seat Max. Inlet Pressure Max. Outlet Pressure Gauge Optional
PD34 1: Inlet/outlet/vent 6: 1/4" MNPT B: Brass K: PCTFE D: 3000 psig K: 50 psig K: psig / kPa Blank: Standard
  3: Inlet/outlet   S: Stainless steel     I: 100 psig P: psig / bar V: Waste gas disposal
            H: 150 psig    
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 