| Home | | Gastec- Kit WPT-132/WPT-133/WPT-135 | |
|
|
|
Waste water test kitWPT-132/WPT-133/WPT-135
Enables concentrations of organic chlorinated solvents (e.g.
tetrachloroethylene, trichloroethylene) present in wastewater to be
easily measured.
Detector tubes to be used
| Substance to be measured |
Tube No. & Name |
Measuring range |
| Trichloroethylene |
132M |
Trichloroethylene |
0.14 - 7.0 mg/l |
| 132LL |
Trichloroethylene |
0.007 - 0.256 mg/l |
| 132L |
Trichloroethylene |
0.056 - 1.95 mg/l |
| 132LC |
Trichloroethylene |
0.1 - 0.4 mg/l |
| Tetrachloroethylene |
133M |
Tetrachloroethylene |
0.13 - 6.3 mg/l |
| 133LL |
Tetrachloroethylene |
0.005 - 0.174 mg/l |
| 133L |
Tetrachloroethylene |
0.052 - 1.93 mg/l |
| 133LC |
Tetrachloroethylene |
0.05 - 0.3 mg/l |
| 1,1,1-Trichloroethane |
135L |
1,1,1-Trichloroethane |
0.4 - 14 mg/l |
How to use
- 1.
- Measure 200mL of wastewater with the beaker,
replace it in the glass jar, seal the opening with a stopper, and shake
it for one minute.
- 2.
- Both ends of the detector tube are broken off, and it is inserted in the syringe or sampling pump (GV-100) for gas sampling.
- 3.
- The stopper of the glass jar is removed, and
measurement is done with the point of the detector tube just above the
surface of the liquid.
- 4.
- After the measuring time is over, the scale on the detector tube is read.
- 5.
- The temperature of the wastewater is measured.
- 6.
-
By using the conversion data of the user manual, calculate the concentration in the wastewater.
|
|
|
|
|
|
|
|
Ancor Sdn Bhd
D-2-4, Setiawalk, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: +6012-921 3877 , 03-58797121
Email: info@ancor.com.my ; ancor.my@gmail.com
|
|
|
 |
|