| Home | | Dwyer- Pressure Transmitters Hazardous Rated | |
|
|
|
Pressure Transmitters
This category has a pressure transmitter that is a microprocessor-based
high performance transmitter. Applications include water and wastewater,
food and beverage, chemical and petrochemical, oil and gas. HART
Communication.
Series 608 Intrinsically Safe Differential Pressure Transmitter
Ranges Down to 0.1" w.c., FM Approved, NEMA 4X
The Dwyer Series 608 Differential Pressure Transmitters
convert positive, negative (vacuum), or differential pressures of
clean, dry air or other non-conductive, non-corrosive gases into a
standard two wire, 4-20 mA output signal. The use of an ultra thin
silicon diaphragm enables precision measurement of differential
pressures as low as 0.1" of w.c. while withstanding high static working
pressures up to 100 psig (6.89 bar). The Series 608 transmitters are FM
approved intrinsically safe for use in the specified hazardous locations
when used with an approved intrinsic safety barrier. The rugged NEMA
4X, stainless steel housing makes this transmitter ideal for use in
industrial and process plant environments.
Calibration Option available under Accessories.
Product Applications
- Lab Fume Hood Control
- Clean Room Applications
- Flow Measurements & Controls
- Filter Monitoring
- Furnace Draft Measurement
- Process Control
Models & Ordering
| Model |
Description |
| 608-00 |
Differential pressure transmitter, range 0-0.1" w.c. |
| 608-00B |
Differential pressure transmitter, range 0.1-0-0.1" w.c. |
| 608-01 |
Differential pressure transmitter, range 0-0.25" w.c. |
| 608-01B |
Differential pressure transmitter, range 0.25-0-0.25" w.c. |
| 608-02 |
Differential pressure transmitter, range 0-0.5" w.c. |
| 608-02B |
Differential pressure transmitter, range 0.5-0-0.5" w.c. |
| 608-03 |
Differential pressure transmitter, range 0-1.0" w.c. |
| 608-03B |
Differential pressure transmitter, range 1.0-0-1.0" w.c. |
| 608-04 |
Differential pressure transmitter, range 0-2.0" w.c. |
| 608-04B |
Differential pressure transmitter, range 2.0-0-2.0" w.c. |
| 608-05 |
Differential pressure transmitter, range 0-5.0" w.c. |
| 608-05B |
Differential pressure transmitter, range 5.0-0-5.0" w.c. |
| 608-06 |
Differential pressure transmitter, range 0-10.0" w.c. |
| 608-07 |
Differential pressure transmitter, range 0-25.0" w.c. |
| 608-10 |
Differential pressure transmitter, range 0-0.1" w.c. |
| 608-10B |
Differential pressure transmitter, range 0.1-0-0.1" w.c. |
| 608-11 |
Differential pressure transmitter, range 0-0.25" w.c. |
| 608-11B |
Differential pressure transmitter, range 0.25-0-0.25" w.c. |
| 608-12 |
Differential pressure transmitter, range 0-0.5" w.c. |
| 608-12B |
Differential pressure transmitter, range 0.5-0-0.5" w.c. |
| 608-13 |
Differential pressure transmitter, range 0-1.0" w.c. |
| 608-13B |
Differential pressure transmitter, range 1.0-0-1.0" w.c. |
| 608-14 |
Differential pressure transmitter, range 0-2.0" w.c. |
| 608-14B |
Differential pressure transmitter, range 2.0-0-2.0" w.c. |
| 608-15 |
Differential pressure transmitter, range 0-5.0" w.c. |
| 608-15B |
Differential pressure transmitter, range 5.0-0-5.0" w.c. |
| 608-16 |
Differential pressure transmitter, range 0-10.0" w.c. |
| 608-17 |
Differential pressure transmitter, range 0-25.0" w.c. |
|
Series 636D Fixed Range Differential Pressure Transmitter
Explosion-proof, 0.5% Accuracy
Series 636D Differential Pressure Transmitter
can be used for measuring pressures of liquids, gases & vapors. All
available ranges have an excellent 0.5% F.S. accuracy with a 4-20 mA
Output standard or optional 1-5 VDC output. The NEMA 4 housing is an all
316 welded construction that is designed to withstand the harshest
environmental conditions. With all 316L wetted materials, this
transmitter is compatible with most media. These units are CSA approved
explosion-proof for use in the specified hazardous locations and meet
NACE standards for off-shore applications.
Product Applications
- Monitoring Differential Pressure for: Oil & Gas Applications,
Level Measurements in Non-Vented Liquid Tanks, Filtration Systems,
Compressor Control, Process Control.
Models & Ordering
| Model |
Description |
| 636D-0 |
Fixed range differential pressure transmitter, range 0-6 psid. |
| 636D-0-LP |
Fixed range differential pressure transmitter, range 0-6 psid. |
| 636D-1 |
Fixed range differential pressure transmitter, range 0-15 psid. |
| 636D-1-LP |
Fixed range differential pressure transmitter, range 0-15 psid. |
| 636D-2 |
Fixed range differential pressure transmitter, range 0-30 psid. |
| 636D-2-LP |
Fixed range differential pressure transmitter, range 0-30 psid. |
| 636D-3 |
Fixed range differential pressure transmitter, range 0-60 psid. |
| 636D-3-LP |
Fixed range differential pressure transmitter, range 0-60 psid. |
| 636D-4 |
Fixed range differential pressure transmitter, range 0-100 psid. |
| 636D-4-LP |
Fixed range differential pressure transmitter, range 0-100 psid. |
| 636D-5 |
Fixed range differential pressure transmitter, range 0-150 psid. |
| 636D-5-LP |
Fixed range differential pressure transmitter, range 0-150 psid. |
| 636D-6 |
Fixed range differential pressure transmitter, range 0-200 psid. |
| 636D-6-LP |
Fixed range differential pressure transmitter, range 0-200 psid. |
| 636D-7 |
Fixed range differential pressure transmitter, range 0-300 psid. |
| 636D-7-LP |
Fixed range differential pressure transmitter, range 0-300 psid. |
| 636D-8 |
Fixed range differential pressure transmitter, range 0-500 psid. |
| 636D-8-LP |
Fixed range differential pressure transmitter, range 0-500 psid. |
|
Series IS626 Intrinsically Safe Pressure Transmitter
For Use In Hazardous Locations
Series IS626 Intrinsically Safe Pressure Transmitter (Male NPT/BSPT Connector with Cable Gland)
|
Series IS626 Intrinsically Safe Pressure Transmitter (Male NPT/BSPT Connector with Male M-12 Connector)
|
The Dwyer Series IS626 Intrinsically Safe Pressure Transmitter
can be used to accurately measure compatible gases and liquids
compatible with its 316/316L Stainless Steel wetted parts. Series IS626
full scale accuracy is 0.25%. Designed for industrial environments with a
NEMA 4X (IP66) housing, this transmitter resists most effects of shock
and vibration. Models are available with a 3' cable or M-12 4 pin
connection.
The IS626 is UL listed for use in Hazardous
(Classified) Locations. The protection method is by Intrinsic
Safety,"ia". It was investigated by UL under UL Standard 913 Sixth
Edition and CSA Standard No. 157-92.
Product Applications
- Monitoring pressure in hazardous environments
- Process
Models & Ordering
| Model |
Description |
| IS626-07-GH-P1-E1-S1 |
Intrinsically safe pressure transmitter, 15 psi pressure range, 4-20 mA output, 1/4"
NPTM, general purpose housing. |
| IS626-08-GH-P1-E1-S1 |
Intrinsically safe pressure transmitter, 30 psi pressure range, 4-20 mA output, 1/4"
NPTM, general purpose housing. |
| IS626-09-GH-P1-E1-S1 |
Intrinsically safe pressure transmitter, 50 psi pressure range, 4-20 mA output, 1/4" NPTM, general purpose housing. |
| IS626-10-GH-P1-E1-S1 |
Intrinsically safe pressure transmitter, 100 psi pressure range, 4-20 mA output, 1/4" NPTM, general purpose housing. |
| IS626-13-GH-P1-E1-S1 |
Intrinsically safe pressure transmitter, 300 psi pressure range, 4-20 mA output, 1/4" NPTM, general purpose housing. |
|
Series ISDP Intrinsically Safe Differential Pressure Transmitter
For Hazardous Zone Pressure and Flow Applications
The SERIES ISDP Differential Pressure
Transmitter provides a 4-20 mA process output, a robust NEMA 4X
enclosure, plus a large LCD display that can be programmed to read in
pressure, velocity or flow. The ISDP offers simplified programming via a
Menu key that enables the user to select: security level; English or
Metric engineering units; pressure, velocity or flow operation, K-factor
for use with various Pitot tubes and flow sensors, circular or
rectangular duct size for volumetric flow operation plus many more. The
Series ISDP Differential Pressure Transmitter is powered on its two wire
loop with 10-35 VDC via its integral M-12 four pin male connector. The
ISDP provides a 0.5% full scale accuracy on ranges from 0.25" w.c. to
100" w.c. as well as bi-directional models up to 10" w.c. These features
make the Series ISDP Differential Pressure Transmitter the ideal
instrument for monitoring pressures or air flows in hazardous zones
having a Class I Div. I Groups A, B, C, D; Class II Div. I Groups E, F,
G; Class III Div. I ratings.
Product Applications
- Hazardous zone pressure control applications
- Hazardous flow and control applications
Models & Ordering
| Model |
Description |
| ISDP-002 |
Intrinsically safe differential pressure transmitter, range 0-0.25" w.c. |
| ISDP-004 |
Intrinsically safe differential pressure transmitter, range 0-1" w.c. |
| ISDP-006 |
Intrinsically safe differential pressure transmitter, range 0-5" w.c. |
| ISDP-007 |
Intrinsically safe differential pressure transmitter, range 0-10" w.c. |
| ISDP-008 |
Intrinsically safe differential pressure transmitter, range 0-25" w.c. |
| ISDP-009 |
Intrinsically safe differential pressure transmitter, range 0-50" w.c. |
| ISDP-010 |
Intrinsically safe differential pressure transmitter, range 0-100" w.c. |
| ISDP-012 |
Intrinsically safe differential pressure transmitter, range -0.25/+0.25" w.c. |
| ISDP-014 |
Intrinsically safe differential pressure transmitter, range -1.0/+1.0" w.c. |
| ISDP-015 |
Intrinsically safe differential pressure transmitter, range -2.5/+2.5" w.c. |
| ISDP-016 |
Intrinsically safe differential pressure transmitter, range -5.0/+5.0" w.c. |
| ISDP-017 |
Intrinsically safe differential pressure transmitter, range -10/+10" w.c. |
|
Series 3100D Explosion-proof Differential Pressure Transmitter
HART® Communication, Push Button Configuration, Rangeability (100:1)
|
|
Series 3100 Explosion-proof Differential Pressure Transmitter
|
|
The Mercoid® Series 3100D Smart Pressure Transmitter
is a microprocessor-based high performance transmitter, which has
flexible pressure calibration, push button configuration, and
programmable using HART®
Communication. The Series 3100D is capable of being configured for
differential pressure or level applications with the zero and span
buttons. A field calibrator is not required for configuration. The
transmitter software compensates for thermal effects, improving
performance. EEPROM stores configuration
settings and stores sensor correction coefficients in the event of
shutdowns or
power loss. The Series 3100D is FM or ATEX approved for use in hazardous
(classified) locations.
The 100:1 rangeability allows the smart transmitter to be configured to
fit any application.
Product Applications
- Flow measurement
- Level monitoring
- Filter or pump differential pressure
- Critical process monitoring
Models & Ordering
| Model |
Description |
| 3100D-1-FM-1-1 |
Smart differential pressure transmitter, range 0-6" w.c. |
| 3100D-1-FM-1-1-LCD |
Smart differential pressure transmitter, range 0-6" w.c. |
| 3100D-2-FM-1-1 |
Smart differential pressure transmitter, range 0-30" w.c. |
| 3100D-2-FM-1-1-LCD |
Smart differential pressure transmitter, range 0-30" w.c. |
| 3100D-3-FM-1-1 |
Smart differential pressure transmitter, range 0-150" w.c. |
| 3100D-3-FM-1-1-LCD |
Smart differential pressure transmitter, range 0-150" w.c. |
| 3100D-4-FM-1-1 |
Smart differential pressure transmitter, range 0-750" w.c. |
| 3100D-4-FM-1-1-LCD |
Smart differential pressure transmitter, range 0-750" w.c. |
| 3100D-5-FM-1-1 |
Smart differential pressure transmitter, range 0-100 psi. |
| 3100D-5-FM-1-1-LCD |
Smart differential pressure transmitter, range 0-100 psi. |
| 3100D-6-FM-1-1 |
Smart differential pressure transmitter, range 0-300 psi. |
| 3100D-6-FM-1-1-LCD |
Smart differential pressure transmitter, range 0-300 psi. |
| 3100D-7-FM-1-1 |
Smart differential pressure transmitter, range 0-1000 psi. |
| 3100D-7-FM-1-1-LCD |
Smart differential pressure transmitter, range 0-1000 psi. |
|
Series 3100MP Explosion-Proof Multiplanar Differential Pressure Transmitter
HART®, Push Button Configuration, Rangeability (100:1)
|
|
|
Series 3100 Explosion-proof Differential Pressure Transmitter
|
|
|
Series 3100MP Explosion-proof Differential Pressure Transmitter
|
|
The Mercoid® Series 3100MP Multiplanar Smart Pressure Transmitter
is a
microprocessor-based high performance transmitter, which has flexible
pressure
calibration, push button configuration, and programmable using HART®
Communication.
The multiplanar design simplifies installation, saving operator time and
money during set
up. The 3100MP can be installed vertically without adaptors or brackets
regardless of the
process connection orientation. The multiplanar footprint fits standard
manifold valves
and averaging flow sensors. The Series 3100MP is capable of being
configured for
differential pressure or level applications with the zero and span
buttons. A field calibrator
is not required for configuration. The transmitter software compensates
for thermal
effects, improving performance. EEPROM stores configuration settings and
stores sensor
correction coefficients in the event of shutdowns or power loss. The
Series 3100MP is FM or ATEX approved for use in hazardous (classified)
locations. The 100:1 rangeability allows the
smart transmitter to be configured to fit any application.
Product Applications
- Flow measurement
- Level monitoring
- Filter or pump differential pressure
- Critical process monitoring
Models & Ordering
| Model |
Description |
| 3100MP-1-FM-1-1 |
Smart differential pressure transmitter, range 0-6.0" wc, with aluminum housing, FM approved, multiplanar |
| 3100MP-1-FM-1-1-LCD |
Smart differential pressure transmitter, range 0-6.0" wc, with aluminum housing, FM approved, multiplanar with LCD |
| 3100MP-2-FM-1-1 |
Smart differential pressure transmitter, range 0-30" wc, with aluminum housing, FM approved, multiplanar |
| 3100MP-2-FM-1-1-LCD |
Smart differential pressure transmitter, range 0-30" wc, with aluminum housing, FM approved, multiplanar with LCD |
| 3100MP-3-FM-1-1 |
Smart differential pressure transmitter, range 0-150" wc, with aluminum housing, FM approved, multiplanar |
| 3100MP-3-FM-1-1-LCD |
Smart differential pressure transmitter, range 0-150" wc, with aluminum housing, FM approved, multiplanar with LCD |
| 3100MP-4-FM-1-1 |
Smart differential pressure transmitter, range 0-750" wc, with aluminum housing, FM approved, multiplanar |
| 3100MP-4-FM-1-1-LCD |
Smart differential pressure transmitter, range 0-750" wc, with aluminum housing, FM approved, multiplanar with LCD |
| 3100MP-5-FM-1-1-LCD |
Smart differential pressure transmitter, range 0-100 psi, with aluminum housing, FM approved, multiplanar with LCD |
| 3100MP-6-FM-1-1 |
Smart differential pressure transmitter, range 0-300 psi, with aluminum housing, FM approved, multiplanar |
| 3100MP-7-FM-1-1 |
Smart differential pressure transmitter, range 0-1000 psi, with aluminum housing, FM approved, multiplanar |
| 3100MP-7-FM-1-1-LCD |
Smart differential pressure transmitter, range 0-1000 psi, with aluminum housing, FM approved, multiplanar with LCD |
|
Series 3200G Explosion-proof Pressure Transmitter
HART® Communication, Push Button Configuration, Rangeability (100:1)
Series 3200G Explosion-proof
Pressure Transmitter
|
A-631, Stainless steel flat type
bracket with SS bolts.
|
BBV-0N, 2-valve block manifold.
|
|
|
|
|
The Mercoid® Series 3200G Smart Pressure Transmitter
is a microprocessor-based high performance transmitter, which has
flexible pressure calibration, push button configuration, and
programmable using HART® Communication. The Series 3200G is capable of
being configured with the zero and span buttons, a field calibrator is
not required for configuration. The transmitter software compensates for
thermal effects, improving performance. EEPROM stores configuration
settings and stores sensor correction coefficients in the event of
shutdowns or power loss. The Series 3200G is FM approved for use in
hazardous (Classified) locations. The 100:1 rangeability allows the
smart transmitter to be configured to fit any application.
Product Applications
- Water and wastewater
- Chemical and petrochemical
- Pulp and paper
- Oil and gas
- Food and beverage
Models & Ordering
| Model |
Description |
| 3200G-1-FM-1-1 |
Smart pressure transmitter, range -14.5 to 21 psi. |
| 3200G-1-FM-1-1-LCD |
Smart pressure transmitter, range -14.5 to 21 psi with LCD display. |
| 3200G-2-FM-1-1 |
Smart pressure transmitter, range -14.5 to 217 psi. |
| 3200G-2-FM-1-1-LCD |
Smart pressure transmitter, range -14.5 to 217 psi with LCD display. |
| 3200G-3-FM-1-1 |
Smart pressure transmitter, range 0 to 725 psi. |
| 3200G-3-FM-1-1-LCD |
Smart pressure transmitter, range 0 to 725 psi with LCD display. |
| 3200G-4-FM-1-1 |
Smart pressure transmitter, range 0 to 3600 psi. |
| 3200G-4-FM-1-1-LCD |
Smart pressure transmitter, range 0 to 3600 psi with LCD display. |
|
Series AT2MS ATEX/IECEx Approved Magnesense® Differential Pressure Transmitter
Series MS in Flame-Proof Enclosure
The ATEX/IECEx Approved Series AT2MS Magnesense® Differential Pressure Transmitter
is an extremely versatile transmitter for monitoring pressure and air
velocity in hazardous areas. This transmitter is loaded with features
such as: field selectable English or metric ranges, field upgradeable
LCD display, adjustable dampening of output signal and the ability to
select a square root output for use with pitot tubes and other similar
flow sensors. Along with these features, the magnetic sensing technology
provides exceptional long term performance and enables the Magnesense®
transmitter to be the solution for a myriad of pressure and flow
applications. Flame-proof enclosures are available in aluminum and can
include a glass window for viewing process on the LCD.
Important notes for installation:
• Cables must be fitted through 1/2" NPT cable gland or ATEX/IECEx conduit (not supplied with instrument).
•
Make sure after cabling to close tight cover and cable gland, in order
to keep IP66 rating (IP65 with option OPV, overpressure relief valve).
• Open cover only after de-energizing instrument.
• Attention: Check local safety rules and warnings on unit and manual for a correct use of the instrument in hazardous area.
Please see SERIES MS for non-ATEX/IECEx approved.
Product Applications
- Monitor pressures in ducts, rooms, or total building pressures
- Filter monitoring
- Local indication of clean room pressures with process signal sent to control room
- Hazardous area pressure measurement and transmitter
|
Series AT2605 ATEX/IECEx Approved 605 Differential Pressure
Series 605 in Flame-Proof Enclosure
The ATEX/IECEx approved SERIES AT2605
Indicating Transmitter provides for both visual monitoring and
electronic control of very low differential pressure in hazardous
locations. The easily read dial gage is complimented by the two-wire, 4
to 20 mA control signal utilizing the time-proven Dwyer® Magnehelic®
gage mechanical design and Series 600 transmitter technology. The
two-wire design simplifies any 4 to 20 mA control loop powered by a 10
to 35 VDC supply. Flame-proof enclosures are available in aluminum and
can include a glass window for viewing process pressure on gage face.
Important notes for installation:
• Cables must be fitted through 1/2" NPT cable gland or ATEX/IECEx conduit (not supplied
with instrument).
• Make sure after cabling to close tight cover and cable gland, in order to keep IP66
rating (IP65 with option OPV, overpressure relief valve).
• Open cover only after de-energizing instrument.
• Attention: Check local safety rules and warnings on unit and manual for a correct
use of the instrument in hazardous area.
Please see SERIES 605 for non-ATEX/IECEx approved.
Product Applications
- Monitor pressures in ducts, rooms, or total building pressures
- Filter monitoring
- Local indication of clean room pressures with process signal sent to control room
- Hazardous area pressure measurement and transmitter
|
|
|
|
|
|
|
|
Ancor Sdn Bhd
D-2-4, Setiawalk, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: +6012-921 3877 , 03-58797121
Email: info@ancor.com.my ; ancor.my@gmail.com
|
|
|
 |
|