ANCOR SDN BHD
Tel: +6012-921 3877 ;
       +603-58797121
Email: info@ancor.com.my ;
           ancor.my@gmail.com
D-2-4, Setia Walk,
Pusat Bandar Puchong,
47160 Puchong, Selangor
   Home      Dwyer- Capacitive Level Switches
         
 
 
 
 
 

Capacitive

Capacitive level switches are sensors with an electrical contact output at a specific liquid, powder, or bulk level. Their traditional use is for non-metallic materials such as: plastics industry, chemical industry, wood industry, ceramic and glass industry, and packing industry. A few models are no maintenance.
 
 
 
 
 
 

Model CLS1 Capacitance Level Switch

For Solids, Liquids or Slurries, Fail-Safe Protection, <1 pF Sensitivity

 
 
 
 
 
 
 
 
 
Model CLS1 Capacitance Level Switch provides reliable point level measurement of solids, liquids and slurries in metallic or non-metallic tanks and vessels. Model CLS1 detects the presence or absence of material in contact with the probe by sensing a change in the capacitance. Electronics provide highly sensitive measurement detection (requires less than a 1 picofarad shift from ambient). State of the art technology ignores material build-up on the vessel sidewall or along the probe assembly. One time calibration is simple with a single multi-turn potentiometer. Red LED on housing indicates sensor status. Unit features an adjustable 1-30 second time delay and a 5 amp, SPDT fail-safe relay output. Model CLS1 can be mounted vertically or horizontally.
 
 
 

Product Applications

 
  • High or low level detection in bins, silos, tanks, hoppers, chutes and other vessels where liquids, solids or slurries are stored.
 
 

Models & Ordering

 
Model Description
CLS1 Capacitance level switch.
 
 
 
 
 
 
 
 
 
 

Series CLS2 Capacitive Level Switch

Powder, Bulk, or Liquids, Auto-Calibration

 
The CLS2 is a capacitive technology level switch that does not have any moving parts - no jams, no wear, nothing to break, and no maintenance. State of the art sensing technology in the CLS2, using impulse RF admittance measurement combined with an active guard, provides excellent level measurement and stability while being insensitive to material buildup. This technology also provides immunity to external RF sources like walkie-talkies and cell phones as well as minimal interference with radio communication or other electronic systems.
 
 
 
 
 
Capacitive level technology can be used for liquids, powders and bulk materials and is great for difficult applications such as slurries, coating products, and liquids and solids. The CLS2 is ideal for level indication in silos, receivers, and transporters in pneumatic conveying systems. The CLS2 can also be used for liquid interface applications to detect the level of two immiscible liquids that have different dielectric constants such as oil and water. Wetted materials of PVDF and 316 SS assure great chemical compatibility and meet food grade requirements.
 
 
 

Product Applications

  • Sewage and wastewater
  • Boilers and steam generators
  • Food and beverage
  • Caustics and acids
  • Pharmaceuticals
  • Reservoirs
  • Sumps
  • Level indication in silos
  • Level monitoring in receivers
  • Transporters in pneumatic conveying systems
 
 

Models & Ordering

 
 
Model Description
CLS2-W11RK1-006 Capacitive level switch, weatherproof, 6" probe
CLS2-W11RK1-019 Capacitive level switch, weatherproof, 19" probe
 
 
 
 
 
 
 
 
 

Series NCS-10 Through Wall Capacitive Sensor

Non-Contact, Thin Profile Level Sensor

 
Series NCS-10 Through Wall Capacitive Sensor features a thin profile with a sensing distance of 10 mm non-flush mounted. The switching points can be altered by means of the push-button teach-in function. 3-wire DC output with selectable make (NO) or break (NC) switching and NPN Alarm. The NCS-10 is designed for front, pipe or plane mounting. Capacitive sensors can detect metallic as well as nonmetallic objects; however, their traditional use is for non-metallic materials such as: plastics industry, chemical industry, wood industry, ceramic and glass industry, and packing industry.
 
 
 
 

Models & Ordering

 
Model Description
NCS-10N Through wall capacitive sensor, NPN.
NCS-10P Through wall capacitive sensor, PNP.
 
 
 
 
 
 
 
 
 

Model FCLS Flush Capacitance Level Switch

Maintenance Free, Economical, Flush Mounting

 
The Model FCLS Flush Capacitance Level Switch is ideal for level measurement of liquids and bulk solids to trigger an alarm or close a filler inlet. No probe design allows for installation where space is constrained or where material flow or material build up would damage a probe. With no moving parts, this level switch assures no jams, no wear, nothing to break, and no maintenance. Comes standard with IP65 housing with a maximum pressure limit of 285 psi (19.7 bar).
 
 
 
 
 

Models & Ordering

 
Model Description
FCLS-01 Flush capacitance level switch.
 
 
 
 
 
 
 
 
 


Ancor Sdn Bhd
D-2-4, Setiawalk, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: +6012-921 3877 , 03-58797121
Email: info@ancor.com.my ; ancor.my@gmail.com