TIO Accessory Totalizer Input/Output
Model TIO totalizer input/output flow monitor and controller
Design Features
- Displays instantaneous, total and accumulated flow rates.
-
Built-in Flow Linearizer (10 point linearization of the flow curve).
-
Up to 47 different volumetric and mass flow engineering units.
-
Large 13mm (0.51") digits for flow rate and 5.5mm (0.21") for Total.
-
Digital RS-232 or RS-485 interface (multi-drop capability of up to 64 devices.)
-
Compact design for unit mount, panel mount, wall mount or field mount applications.
-
User-programmable, optically-isolated pulse output.
-
Two programmable, optically-isolated, digital outputs.
-
Flow controllers, set point command control via local LCD or digital interface.
-
Programmable set point table with ramping up/down capability up to 16 steps.
-
Programmierbare Sollwerttabelle mit Beschleunigungs/Entschleunigungsfunktion mit bis zu 16 Schritten.
-
Free Configuration and Monitoring Utility software.
For flow meters and controllers with
analog 0-5 (5-10) (0-10)Vdc, 4-20mA input output interface, where flow
indications / control and to-talizers or alarm functions are required.
Also when re-transmission of the flow rate and/or totalizer functions
via optically-isolated pulse output or serial communication is desired.
Local or programmable set point control for flow controllers (no host PC
presence required). Ac-tivation of user-supplied equipment via
programmable optically-iso-lated digital outputs when flow alarms or
totalizers events are active.
The
graphical LCD display has large 13mm (0.51") digits for flow rate and
5.5mm (0.21") for total and can be set by user to simultaneously show
different combination of the flow parameters: flow rate, totalizers,
flow alarms, and diagnostic events. All configuration parameter
set-tings are easily accessed via a simple user-interface menu driven by
a 6 button key-pad which can be password-protected.
Signal Input and Signal Output
- 0-5 Vdc (Input/Output)
- 5-10 Vdc (Output only)
- 0-10 Vdc (Input/Output)
- 4-20 mA (Input/Output)
For
flow meters and / or flow controllers, TIO provides jumpers selectable
for 0-5 Vdc or 4-20 mA analog set point control signals. The flow rate
set point can be adjusted lo-cally via key-pad, remotely via host PC
using digital communication interface, or pro-grammed in advance using
built-in 16 steps batch table with ramping up/down support.
Programmable Pulse Output
The
programmable flow pulse output is operating independently from
totalizers and based on configuration settings can provide pulse
frequency proportional to instantaneous fluid flow rate.
The LCD/keypad and digital communication interface commands are provided to:
- Enable/Disable Pulse Output
- Configure Pulse Output start flow rate (in % of full scale)
- Configure the Unit/Pulse value (in current volumetric or mass flow units)
- Configure Pulse Active On Time (10 - 6550 ms)
Programmable Totalizers
TIO
provides two independent programmable flow totalizers. Both totalizers
are updated every 100 ms and can be set to activate different events.
Main totalizer accumulated total is backed-up in EEPROM memory every
second.
The LCD/keypad and digital communication interface commands are provided to:
- Enable/Disable totalizing the flow
- Start the totalizer at a preset flow rate (in % of full scale)
- Assign action at a preset total volume (Event Volume)
- Configure power on delay (in seconds)
- Configure Auto Reset at preset volume
- Configure Auto Reset delay (in seconds)
- Reset the totalizer to ZERO
Programmable Alarms
TIO
provides the user with a flexible alarm/warning system that monitors
the fluid flow for conditions that fall outside con-figurable limits as
well as visual feedback for the user via the LCD or via an
optically-isolated output. The flow alarm has several attributes which
can be configured by the user via LCD/Keypad or digital communication
interface:
- Enable/Disable flow alarm
- Low flow alarm settings (in % of full scale)
- High flow alarm settings (in % of full scale)
- Flow alarm action delay
- Flow alarm action latch mode
Digital Communication
All
process data and settings can be read and modified manually via local
LCD Key-pad or through the digital RS-232 or RS-485 communication
interface. Proprietary ASCII software interface command set and free
Communica-tion Utility software are provided.
|
|
|
|
|
|
|
|