GPR-15 XP PPM Explosion-Proof Oxygen Transmitter
- Explosion-proof
PPM oxygen transmitter measures O2 concentrations from 100 PPB to 1%.
- Meets standards for Class 1, Division 1, Groups B, C, D.
- Features an
advanced galvanic trace PPM oxygen sensor, a 24 month operating life, a
proven electronic platform, flame arrestors, a stainless steel sample
system, and two (2) wire loop power.
|
GPR-25 XP % Explosion-Proof Oxygen Transmitter
- Explosion-proof percent oxygen transmitter measures O2 concentrations from 0.05% to 100%.
- Analyzer meets
standards for Class 1, Division 1, Groups B, C, D hazardous areas.
- Features an advanced galvanic trace PPM oxygen sensor, a 36 month
operating life with no periodic maintenance required, a proven
electronic platform, flame arrestors, a stainless steel sample system,
and two (2) wire loop power.
|
Intrinsically Safe
Oxygen Transmitter Intrinsically Safe
GPR-2500 AIS % Oxygen Transmitter
- ATEX
and cUL certified analyzer measures O2 concentrations from 0.05% to
100%.
- Features certification to ATEX Directive 94/9/EC and cUL designed
exclusively for Natural Gas applications.
- This analyzer features an
advanced galvanic oxygen sensor, a 36 month operating life, menu driven
controls, two (2) field selectable alarm set points, and a stainless
steel sample system.
- Pictured with the optional A-3393 modular sample
system designed to remove moderate amounts of free liquids and H2S from
natural gas streams.
|
GPR-2500 IS % O2 Transmitter
- Intrinsically
safe % oxygen transmitter with integral safety barrier, ATEX, cUL, and
CSA certified 2-wire loop powered 4-20 mA transmitter measures O2
concentrations from 0- 25% with 0-1% full scale low range.
- Designed
exclusively for Natural Gas applications.
- This transmitter features an
advanced galvanic oxygen sensor, a 36 month operating life, and menu
driven controls.
|
GPR-2500 N 2-Wire Loop Powered % Oxygen Transmitter
- NEMA 4 enclosure two-wire loop powered %O2 transmitter features ATEX certification, galvanic
oxygen sensor, a 24 month operating sensor life, menu driven controls,
and a stainless steel sample system, NEMA 4 enclosure suitable for
outdoor use.
|
GPR-2500 % Oxygen Transmitter
- ATEX approved Intrinsically safe 2-wire loop powered %O2 transmitter for measuring %O2 concentrations in a gas mixture.
- Transmitter is a two wire loop powered and features
certification to ATEX Directive 94/9/EC with intrinsic safety barrier,
an advanced galvanic type % oxygen sensor, a 32 month operating sensor
life, menu driven controls, and a stainless steel sample system,
|
GPR-2800 AIS-LD % Oxygen Transmitter
- Industrial ATEX and cUL certified % oxygen transmitter, measures O2.
- Features certification to ATEX Directive 94/9/EC. This
analyzer features an advanced galvanic percent oxygen sensor, a 32
months operating sensor life, menu driven controls, and two (2) field
selectable alarm set points.
- Pictured with optional A-3393 modular
sample system designed to remove moderate amounts of free liquids and
H2S from natural gas streams.
|
|
Ppm Oxygen Transmitter Intrinsically Safe
GPR-1500 AIS PPM O2 Transmitter
- Natural
gas ATEX, cUL approved PPM Oxygen Transmitter, 0-10 PPM low range,
measures O2 concentrations from 0.01 PPM to 1%.
- The GPR-1500 AIS
features certification to ATEX Directive 94/9/EC and
cUL designed exclusively for Natural Gas applications.
- This analyzer
features an advanced galvanic trace PPM oxygen sensor, a 18 month
operating sensor operating life, menu driven controls, two (2) field
selectable alarm set points.
- Pictured with optional A-3393 modular
sample system designed to remove moderate amounts of free liquids and H2S from natural gas streams.
|
GPR-1500 AIS-LD PPM O2
- ATEX
and cUL certified PPM oxygen analyzer measures O2 concentrations from
100 PPB to 1%.
- Features certification to ATEX Directive 94/9/EC and cUL
designed exclusively for natural gas applications.
- This analyzer
features an innovative sample system that efficiently removes large
amounts of free liquids from gas streams, an advanced galvanic trace PPM
oxygen sensor, a 24 month operating sensor life, menu driven controls,
and two (2) field selectable alarm set points.
|
GPR-1500 D PPM O2 Transmitter
- ATEX certified 2-wire loop powered PPM oxygen transmitter, 0-100 PPM low range, measures O2 concentrations from 0.1 PPM to 1%.
- The GPR-1500 D features.
-
certification to ATEX Directive 94/9/EC
-
an advanced galvanic trace PPM oxygen sensor
-
24 month operating sensor life
-
menu driven controls and
-
a stainless steel sample system.
|
GPR-1500 IS ATEX, cUL Approved PPM O2 Transmitter
- ATEX and
cUL approved 2-wire loop powered transmitter, 0-10 PPM low range,
measures O2 concentrations from 0.01 PPM to 1%.
- The 2-wire transmitter features certification to ATEX Directive 94/9/EC,
and cUL designed exclusively for Natural Gas applications, an advanced
galvanic trace PPM oxygen sensor, an 18 month operating sensor life, and
menu driven controls.
- Pictured with optional A-3393 modular sample
system designed to remove moderate amounts of free liquids and H2S from
natural gas streams.
|
GPR-1500 N PPM O2 Transmitter
- ATEX certified PPM oxygen transmitter measures O2 concentrations from 0.1 PPM to 1%.
- The GPR-1500 N is two wire loop powered and features an advanced galvanic oxygen sensor, a 24 month operating sensor life, menu driven controls, and a stainless steel sample system
|
GPR-1500 PPM O2 Transmitter
- ATEX approved Intrinsically safe 2-wire loop powered PPM oxygen transmitter 0-10 PPM low range, for measuring O2 from 0.1 PPM to 1%. The transmitter features
-
certification to ATEX Directive 94/9/EC
-
an advanced galvanic trace PPM oxygen sensor
-
24 month operating sensor life
-
menu driven controls and
-
a stainless steel sample system.
|
GPR-1800 AIS PPM O2 Transmitter
- Industrial
ATEX and cUL approved PPM oxygen transmitter, 2 oxygen alarms, 0-10 PPM
low range, measures O2 concentrations from 0.01 PPM to 1%.
- Features
certification to ATEX Directive 94/9/EC and
cUL.
- This transmitter features an advanced galvanic trace PPM oxygen
sensor, a 18 month operating sensor life, menu driven controls, and two
(2) field selectable alarm set points.
- Pictured with optional A-3393
modular sample system designed to remove moderate amounts of free
liquids and H2S from natural gas streams
|
GPR-1800 AIS-LD PPM O2
- ATEX
and cUL certified PPM oxygen transmitter, liquid drain to remove
condensate, 0-10PPM low range, two oxygen alarms, measures O2
concentrations from 0.01 PPM to 1%.
- Features certification to ATEX
Directive 94/9/EC and cUL designed exclusively for Natural Gas applications.
- This
analyzer features an advanced galvanic trace PPM oxygen sensor, a 18
month operating sensor life, menu driven controls, and two (2) field
selectable alarm set points.
- Pictured with optional A-3393 modular
sample system designed to remove moderate amounts of free liquids and
H2S from natural gas streams.
|
GPR-1800 IS PPM ATEX, cUL O2 Transmitter
- Industrial
ATEX, cUL approved 2-wire loop powered transmitter, 0-10 PPM low range,
measures O2 concentrations from 100 PPB to 1%.
- Explosion proof oxygen analyzer has a features
certification to ATEX Directive 94/9/EC, an advanced galvanic trace PPM
oxygen sensor, a 24 month operating life, menu driven controls, and two
(2) wire loop power.
|
GPR-1800 IS-LD ATEX & cUL PPM Oxygen Transmitter
|
GPR-7100 PPM H2S Analyzer
- ATEX certified Portable PPM H2S analyzer measures H2S concentrations from 1 PPM to 2000 PPM.
- Features an advanced trace H2S
sensor for measuring trace levels of H2S in various gas streams, a 24
month operating life with no periodic maintenance required, user
friendly digital electronics, a stainless steel sample system that
includes a coalescing filter and flow control, and a compact robust
enclosure selected for the demands of industrial field use.
|
|
|
|
|
|
|
|
Ancor Sdn Bhd
D-2-4, Setiawalk, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: +6012-921 3877; +6018-623 5135,
Fax: 6018-635 1593
Email: info@ancor.com.my ; ancor.my@gmail.com
|
|
|
 |
|