GPR-35 AMB safety monitors
- Ambient air monitor measures O2 concentrations from 0% to 25%.
- Features
proprietary compensation for changes in barometric pressure that
virtually eliminates the false alarms associated with competitive
monitors.
- The enhanced stability of the GPR-35 makes it ideal for oxygen
deficiency monitoring in ambient areas and confined spaces.
- When needed
the most, battery back-up provides eight (8) hours of continuous use in
full alarm mode.
- In addition to OSHA’s 20.0%, 19.5% alarm set points
this monitor offers additional standard features along with a variety of
options that greatly enhance the usability of this device.
|
GPR-2500 S AMB O2 transmitter
- ATEX
certified ambient air monitor/oxygen transmitter measures O2
concentrations with 0.1% resolution.
- The monitor is 2-sire loop powered
with ATEX Directive 94/9/EC (with external intrinsic safety barrier), an
advanced galvanic oxygen sensor, 36 month operating life, menu driven
controls, and NEMA 4 enclosure.
|
GPR-2500 SN AMB % O2 Monitor (Oxygen Transmitter)
- GPR-2500
SN % O2 ambient air monitor two-wire loop powered monitor features ATEX
certification, an advanced galvanic oxygen sensor, 36 month operating
life, menu driven controls, and NEMA 4 enclosure for outdoor use.
|
GPR-2800 AIS-S % O2 Ambient Air Monitor (Oxygen Transmitter)
- GPR-2800
AIS-S % O2 ambient air monitor features ATEX and cUL certification,
measures O2 in ambient air, an advanced galvanic oxygen sensor, a 36
month operating life, menu driven controls, and two field selectable
alarm set points
|
GPR-2800 IS-S % Oxygen Transmitter-Ambient Air Monitor
- GPR-2800
IS-S percent oxygen transmitter measures O2 concentrations in ambient
air for personnel safety in hazardous areas.
- Features certification to
ATEX Directive 94/9/EC, and cUL, an advanced galvanic oxygen sensor, a
36 month operating life, menu driven controls, and two (2) wire loop
power.
|
GPR-2835 AIS AMB O2 Safety Monitor
|
GPR-2835 IS AMB O2 Safety Monitor
- ATEX approved ambient O2 monitor for hazardous areas
-
2-wire loop powered
-
0.1% resolution.
-
advanced galvanic oxygen sensor, 32 months operating life
-
menu driven controls
-
does not requirement external safety barrier. |
GPR-7500 AIS-S AMB H2S Oxygen Transmitter
- ATEX and cUL certified PPM hydrogen sulfide ambient monitor, 2 H2S alarms, detects H2S down to 1 PPM.
- The
intrinsically safe design conforms to the ATEX and cUL directives for
use in hazardous areas.
- The innovative design makes it completely field
serviceable.
- Unlike competing solutions, there is no need for external
programming/control accessories such as a magnetic wand, as the user can
interface directly with the monitor through menu driven controls.
- The
electrochemical sensor is also easily accessible thereby eliminating the
need to declassify the monitored areas before service.
|
GPR-7500 IS AMB H2S Safety Transmitter
- ATEX and cUL approved 2-wire loop powered ambient hydrogen sulfide monitor
- intrinsically safe
- sensitivity 1 PPM H2S
- menu driven touch panel controls
- easy access to the sensor for service
- 4-20 mA Loop Power
|
|
|
|
|
|
|