Industrial Sensors

 


Industrial Percent Oxygen Sensors

 
 
 
 
GPR-11-32 % Oxygen Sensor
 
  • GPR-11-32 % oxygen sensor is a galvanic type oxygen sensor and offers excellent stability and accuracy under stringent applications.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen
  • This sensor is available with following connections
  • GPR-11-32RT          Phone Jack
  • GPR-11-32-4              4-Pin connection
  • GPR-11-60-4             4-Pin connection with 60 months life in air
 
 
 
GPR-11-917-J % Industrial Oxygen Sensor
 
  • Advanced GPR-11-917-J replaces R-17A % oxygen sensor 
  • This galvanic type oxygen sensor offers excellent stability and accuracy under stringent applications.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen.   
  • OEM Equipment:
  • Teledyne R-17A
 
 
 
GPR-11-917-M Industrial % Oxygen Sensor
 
  • GPR-11-917-M replaces R-22A % oxygen sensor.
  • galvanic type oxygen sensor with excellent stability and accuracy under stringent applications.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen.   
  • OEM Equipment:
  • Teledyne R-22A
 
 
PSR-11-21 % Oxygen Sensor – Replacement for B1 Oxygen Sensor
  • PSR-11-21 replaces B1 OX3 and P2 oxygen sensors.
  • Advanced galvanic type % oxygen sensor offers excellent stability and accuracy under stringent applications.
  • All oxygen sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen.
  • OEM Equipment:
  • AMI P2 Sensor
  • GE Sensing Panametrics OX-3 Sensor
  • Teledyne B-1 Sensor
 
 
PSR-11-23 % O2 Sensor
 
  • PSR-11-23 replaces B3 oxygen sensor.
  • The galvanic type % oxygen sensor offers excellent stability and accuracy under stringent applications.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen.   
  • OEM Equipment:
  • AMI P2 Sensor
  • Teledyne B-3 Sensor
 
 
 
PSR-11-52 Percent Oxygen Sensor
  • PSR-11-52 replaces E-2 percent oxygen sensor .
  • The galvanic type oxygen sensor offers excellent stability and accuracy under stringent applications.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen.   
  • OEM Equipment:
  • Teledyne 329
  • Teledyne 3290
  • Teledyne E-2 Sensor
 
 
PSR-11-54 % Oxygen Sensor
  • Advanced PSR_11-54 replaces C-3 % oxygen sensor but with 90% full scale response time of only 7 sec.
  • This galvanic type % oxygen sensor offers excellent stability and accuracy where a fast response is critical.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen.   
  • OEM Equipment:
  • AMI P2 Sensor
  • GE Sensing Panametrics OX-3 Sensor
  • Teledyne C-3 Sensor
 
 
PSR-11-75-KE Percent Oxygen Sensor
  • Advanced PSR-11-75-KE replaces Figaro KE-25 percent oxygen sensor.
  • This galvanic type oxygen sensor offers excellent stability and accuracy in gas streams containing CO2.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen.
  • Recommended for use in measuring oxygen in gas mixtures containing CO2
  • OEM Equipment:
  • Various OEM Analyzers
  • Figaro KE-25 (Japan Storage)
 
 
PSR-11-213 % O2 Sensor
 
  • Advanced PSR-11-213 replaces B-1 and B-1C.
  • This galvanic type % oxygen sensor offers excellent stability and accuracy in gas mixtures containing lighter gases such as hydrogen and helium.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen.
  • *** Use for H2, He, hydrocarbon gas    
  • OEM Equipment:
  • Teledyne B-1 and B-1C Sensors
 
PSR-11-233 % Oxygen Sensor
  • PSR-11-233 replaces B3 oxygen sensor.
  • This galvanic type oxygen sensor offers excellent stability and accuracy in gas mixtures containing hydrogen and helium.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen.
  • ***Use for measuring oxygen in gas mixtures containing H2, He, lighter Hydrocarbon gas    
  • OEM Equipment:
  • AMI P2 Sensor
  • Teledyne B-3 and B-3C Sensor
 
 
PSR-11-330 % Oxygen Sensor
  • Advanced galvanic type oxygen sensor with excellent stability and accuracy under stringent applications.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen.   
  • OEM Equipment:
  • AMI P4 Sensor
  • Analox C3SA Sensor
  • Teledyne C-3 Sensor
 
 
SAF-11-02 % Oxygen Sensor
  • SAF-11-02 replaces IST SAF-11-02-I % oxygen sensor.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen.
  • OEM Equipment:
  • IST – Int’l Sensor Technology
  • IST SAF-11-02-I Sensor
 
 
XLT-11-15 % Oxygen sensor
  • XLT-11-15 replaces A-3, A-5 , OX-4 and P3 % oxygen sensor.
  • This galvanic type oxygen sensor offers excellent stability and accuracy in gas mixtures containing any level of CO2.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of
  • ***Required to measure oxygen in gas mixtures with CO2 > 0.5%    
  • OEM Equipment:
  • AMI P3 Sensor
  • GE Sensing Panametrics OX-4 Sensor
  • Teledyne A-3, A-5
 
 
 
 
 
 
 
 
 

Galvanic Oxygen Purity Sensor

 
 
 
Galvanic Oxygen Purity Sensor
An innovative and cost effective solution that provides 2 years of continuous measurements of up to 100% oxygen concentrations in a maximum suppressed range of 90-100% full scale with minimum drift, extended periods between calibration, unaffected by vibration and minor amounts of particulates and moisture
 
 
 
 

Industrial Pico Ion Ppb Oxygen Sensors

 
 
GPR-12-2000MS Pico-Ion MS Series Sub-PPM Oxygen Sensor
 
  • GPR-12-2000MS sub-PPM oxygen sensor/portable oxygen analyzer drawing upon the features of the UHP sensor, the MS sensor provides the signal output and stability required for oxygen analysis above 5 PPB to fill a much needed cost effective solution between expensive sub-PPB sensors and the limitations of historical galvanic trace PPM sensors.  
  • The MS and UHP series oxygen sensors are specifically designed UHP and MS series oxygen analyzers Model, GPR-1600 UHP, GPR-1600MS, GPR-1200MS and GPR-18
 
 
 
 
GPR-13-2000UHP Pico-Ion UHP Series PPB Oxygen Sensor
 
  • GPR-13-2000 UHP ultra high sensitivity PPB oxygen sensor represents real breakthrough in sensor technology; it uses a proprietary sensing electrode material and a gas chamber design that maximizes the rate of reaction above the sensing electrode while minimizing both the amount of oxygen that dissolves into the electrolyte and the temperature dependence of the sensor’s output, thereby ensuring long-term stability.
  • This compact self contained package requires no maintenance or periodic addition of chemicals and is easily replaced at the end of its 12 month service life.
  • The capabilities of the resulting sensor are:  
  • This sensor is specifically designed for Advanced Instruments, Inc., PPB oxygen analyzer Model GPR-1600UHP
 
 
 
 
 

Industrial Trace Ppm Oxygen Sensors

 
 
 
GPR-12-333 PPM Oxygen Sensor
 
  • GPR-12-333  PPM O2 sensor is ideal for measuring oxygen 0-10 PPM in a gas mixture.
  • This innovative sensor design carries over many of the features of the traditional galvanic oxygen sensor but poses much higher sensitivity, stability and high signal to noise ratio with 24 months operating life thus offerring effective analyzer solution for measuring low levels PPM oxygen analysis   
  • Designed to trace oxygen analyzer, explosion proof, intrinsically safe transmitters and portable analyzers.  
  • GPR-1600
  • GPR-1200
  • GPR-1100
  • GPR-18
  • GPR-1800 Series
  • GPR-1500 Series
 
 
PSR-12-223-L
 
 
  • PSR-12-223_L replaces Teledyne L-2 and L2C ppm oxygen sensor.
  • This advanced galvanic type oxygen sensor offers excellent stability and accuracy under stringent applications.
  • All sensors are subjected to the most extensive stability test.    
  • OEM Equipment:
  • Teledyne 3000 TA/TA-XL/TB
  • Teledyne Insta Trans
  • Teledyne OT-3
  • Teledyne L-2, L-2C Sensors
 
 
PSR-12-223-IT
 
 
  • PSR-12-223-IT replaces Teledyne insta-trace ppm oxygen sensor.
  • This advanced galvanic type oxygen sensor offers excellent stability and accuracy under stringent applications.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen.   
  • OEM Equipment:
  • Teledyne 3000 T
  • Teledyne Insta Trans
  • Teledyne OT-3
  • Teledyne Insta Trace Oxygen Sensor
 
 
PSR-12-223 Oxygen Sensor-Replacement for B2C, OX1 and T1 Sensor
  • PSR-12-223 replaces B2, B2C, OX1 and T1 sensor.
  • The sensor is galvanic type oxygen sensor with excellent stability and accuracy under stringent applications.
  • All sensors are subjected to the most extensive stability test.
  • OEM Equipment:
  • AMI T1 Sensor
  • GE Sensing Panametrics OX-1 Sensor
  • Teledyne B-2/C/CAP/C-XL Sensor
  • Teledyne M-2 Sensor
  • Teledyne S-2 Sensor
  • Teledyne Z-2 Sensor
 
 
XLT-12-123 PPM Oxygen Sensor-Replacement for A2C, OX2 and T2
  • XLT-12-123, replaces A2C, OX2 & T2,
  • This PPM oxygen sensor is galvanic type oxygen sensor with excellent stability and accuracy under stringent applications.
  • All sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen.
  • ***Recommended in gas mixtures with CO2 > 0.5%
  • OEM Equipment:
  • AMI T2 Sensor
  • GE Sensing Panametrics OX-2 Sensor
  • Teledyne A-2, A-2C Sensors
 
 
 
 
 
 
 
 
 
 
 
 
 
Ancor Sdn Bhd
D-2-4, Setiawalk, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: +6012-921 3877; +6018-623 5135,
Fax: 6018-635 1593  