S012152 Sun Shade/Collector Cone
- Stainless steel accessory protects against elevated temperatures due to
direct sunlight and extends the detector footprint for detecting lighter
than air gases.
|
S012130 Mounting bracket kit
- Enables mounting to a wall or 2" (50mm) pipe. Comprises: bracket,
straps/nuts/bolts for pipe-mounting.
- (Not required if IRmax is being
fitted to a junction box using a spigot gland.) Wall-mounting fixings
must be supplied by the installer.
|
S012147 Spigot gland (M20)
- Enable IRmax to be connected to an auxiliary junction box. 5-wire, ATEX and IECEx certified.
|
S012169 Duct mounting kit
- Enable monitoring of ducts measuring from 300mm to 3 metres wide,
air-flows from 4 to 20 metres per second.
- Supplied with mounting flange
(stainless steel) and tube which is to be cut so that it protrudes
half-way across the duct.
|
C011301 Remote calibration box (GRP)
- Suitable for use in offshore environments and enables remote calibration
of IRmax via connection of a hand-held IR Display and test gas.
- GRP
(glass-fibre reinforced polyester) enclosure fitted with lead connectors
and a retaining clip for an IRmax remote calibration pipe.
- Requires an
I.S. connecting lead, and the IRmax detector must be fitted with an
I.S. Barrier Module.
|
C011204/2 Remote calibration box (aluminium)
- Enables remote calibration of IRmax via connection of a hand-held IR
Display and test gas.
- Aluminium enclosure fitted with lead connectors
and a retaining clip for an IRmax remote calibration pipe.
- Requires an
I.S. connecting lead, and the IRmax detector must be fitted with an I.S.
Barrier Module. Suitable for use in on-shore, non-saline environments
only.
|
M041007 Calibration cap
- Fits over the standard weatherproof cap to enable calibration where local air speed exceeds 2 metres per second.
|
- Replaces standard weatherproof cap to enable calibration where local air speed exceeds 2 metres per second.
|
S012827 PC Communications kit
- Communications module supplied with a software CD and USB cables for PC
and IRmax detector connection.
- Enables zeroing, calibration, gas type
changes etc.
- Not suitable for use in a hazardous area.
|
S012295 316 stainless steel Exd junction box
- Enables IRmax to be connected on an RS-485 Modbus network.
- Two cable
gland entries, five terminals suitable for 2.5mm2 cables.
- A Spigot Gland
is required if IRmax is to be connected directly. ATEX/IECEx certified
for Gas and Dust hazardous areas.
|
C01197 GRP Exe junction box
- Provides compliance with NORSOK standards, which stipulate detectors
must have an Exe cable termination area.
- GRP Exe junction box with one
cable gland entry on the left-side, fitted with a six-way terminal
block suitable for 2.5mm2 cables.
- A Spigot Gland is required if IRmax is
to be connected directly.
|
|