ANCOR SDN BHD
Tel: +6012-921 3877 ;
       +6018-623 5135 ;
       +603-58797121
Fax:+6018-635 1593
Email: info@ancor.com.my ;
           ancor.my@gmail.com
D-2-4, Setia Walk,
Pusat Bandar Puchong,
47160 Puchong, Selangor
   Home      Omega Instruments - Lab Equipment      Mass Flow Device
 
 
 
 

Mass Flow Devices

 
 
 
FMA-PC16
 
PORTABLE MASS FLOWMETER AND CALIBRATION KIT
 
  • Ranges of 0 to 0.5 SCCM up to 0 to 1500 SLM
  • <10 ms Response Time—Field Adjustable
  • 30+ Gas Calibrations, Including Air, Ar, CH4, CO, CO2, Ethane, H2, He, N2, N2O, Neon, O2, Propane, Butane, Iso-Butane, Acetylene, Ethylene, Krypton, Xenon, and Sulfur Hexafluoride

 
 
 
FMA-1600A
 
Mass and Volumetric Flow Meters
 
 
  • Ranges of 0 to 0.5 SCCM Up to 0 to 3000 SLM
  • <10ms Response Time—Field Adjustable
  • 30+ Gas Calibrations with Every Unit: Air, Ar, CH4, CO, CO2, Ethane, H2, He, N2, N2O, Neon, O2, Propane, Butane, Acetylene, Ethylene and more
 
FMA-LP1600A
 
LOW PRESSURE DROP GAS MASS FlowMeters
 
 
  • Ranges of 0 to 0.5 SCCM Up to 0 to 500 SLM
  • Reports Mass Flow, Volumetric Flow, Temperature, and Pressure
  • <10 ms Response Time—Field Adjustable
  • 30+ Gas Calibrations, Including Air, Ar, CH4, CO, CO2, Ethane, H2, He, N2, N2O, Neon, O2, Propane, Butane, Iso-Butane, Acetylene, Ethylene, Krypton, Xenon, and Sulfur Hexafluoride
 
FMA900A
 
Industrial Air Velocity Transmitter with Built-In Relay
 
  • Air Velocity Range Up to 12,000 FPM (60.9 m/sec)
  • 2% Full Scale Accuracy
  • Hot Wire Air Velocity Sensor Design
  • Two Sensor Probe Configurations: Fixed Mount and Remote Probe
  • 250 msec Response Time
  • Adjustable High Alarm Set Point
 
FMA-A2000 Series
 
Mass Flowmeters and Controllers With Or Without Integral Display
 
 
  • ±1% Accuracy
  • Linear Output
  • Low Cost
  • Thermal Technology
  • For Flow Rates up to 75 SLM
  • Power Supply Included
  • Comes standard with 5-point NIST cert
 
 
 
FMA-2600 SERIES
 
Mass Flow Controllers with 20+ Gas Select Function
 
 
 
  • 20+ Gas Calibrations, Including: He, O2 , Neon, N2O, N2, Air, Argon, CO, CO2, Methane, Ethane, Propane, Butane, Acetylene, Ethylene, H2
  • Pressure, Temperature, Volumetric & Mass Flow Simultaneously Displayed
  • Easy Operator Push Button Interface
 
FMA-LP2600A
 
Low Pressure Drop Gas Mass Flow Controllers For Clean Gases
 
 
  • 130+ Gas Calibrations Including Pure and Mixed Gases
  • Pressure, Temperature, and Mass Flow Simultaneously Displayed
  • Easy-to-Use Pushbutton Interface
  • NIST Traceability Standard
  • Full Scale Ranges from 0.5 SCCM to 500 SLM
 
HHF1000 series
 
Handheld Air Velocity/Temperature Meter with Wireless option
 
 
  • Measures Air Velocities up to 5000 FPM (25.4m/sec)
  • Measures Air Temperature up to 121°C (250°F)
  • 1.5% Full scale accuracy (Velocity)
  • 0.5% Full scale accuracy (Temperature)
  • Fixed Probe and Telescopic remote probe configurations
 
 
 
 
 
Ancor Sdn Bhd
D-2-4, Setiawalk, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: +6012-921 3877; +6018-623 5135,
Fax: 6018-635 1593  
Email: info@ancor.com.my ; ancor.my@gmail.com